Click on any of the items listed below for further details.
|
|
25 kw Cummins / Mitsubishi (Sound-Attenuated, 2.4L 4 Cyl. Mitsubishi, 439 Hours, Mfg. 2016) Natural Gas/LP Genset
25 KW CUMMINS / MITSUBISHI NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2016 -Model Number: C25 N6 -Serial Number: E160951515 -Spec: A -Standby Rated at 25 kw / 25 kva -Setup 120/240 Volt, Single Phase ONLY (104.2 Amps) -NOT Reconnectable to Other Voltages -4 Wire -60 Hertz, 1800 RPM, 1.0 PF -12 Battery Volts -Powered by a 2.4L 4 Cylinder Mitsubishi Natural Gas / Propane Engine -Factory Setup For Vapor Propane / Natural Gas Use -Model Number: 4G64S4M -Serial Number: SQX6574 -Skid-Mounted -Radiator Cooled -Sound-Attenuated Enclosure -PowerCommand 1302 Control Panel -125 Amp 2 Pole Square D Mainline Circuit Breaker -Jacket Water Heater -Alternator -Battery Charger -Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed & CSA Approved -439 Total Hours Since New -Dimensions: 72"L x 34"W x 46"H -LOAD BANK TESTED -(9) IN STOCK -- $10,500 ea. |
|
|
25 kw Onan / GM (Enclosed, 3.0L 4 Cyl. GM, 565 Hours, Mfg. 2011) Natural Gas/LP Genset
25 KW ONAN / GM NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2011 -Model Number: GGMB-9235897 -Serial Number: L110287442 -Spec: C -Standby Rated at 25 kw, 3 Phase or 25 kw, Single Phase -Setup 120/240 Volt, Single Phase (104.2 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM, 1.0 PF -12 Battery Volts -Powered by a 3.0L Inline 4 Cylinder GM Natural Gas / Propane Engine -Factory Setup For Vapor Propane / Natural Gas Use -Model Number: PSI-3.0L -Serial Number: 3.0L57582 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -PowerCommand 1302 Digital Control Panel -125 Amp 2 Pole Square D Mainline Circuit Breaker -Jacket Water Heater -Alternator -Woodward L-Series Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed & CSA Approved -565 Total Hours Since New -Dimensions: 65"L x 31"W x 46"H -LOAD BANK TESTED -(10) IN STOCK -- $10,500 ea. |
|
|
30 kw Katolight / GM (Open Frame, 4.3L GM V6, 209 Hours, Mfg. 2008) Natural Gas/LP Genset
30 KW KATOLIGHT / GM NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2008 -Marathon Generator End -Generator Set Model Number: NL30PG6 -Generator Set Serial Number: 302812-1-1-1008 -Standby Rated at 30 kw, 3 Phase or 30 kw, Single Phase -Currently Setup 120/208 Volt, 3 Phase (104 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 4.3L GM V6 Vortec Natural Gas / Propane Engine -Engine Model Number: GM-4.3L -Engine Serial Number: 4P3L49178 -Skid-Mounted -Radiator Cooled -Open Frame -Kassec 1.5 Analog Control Panel -125 Amp 3 Pole GE Mainline Circuit Breaker -Jacket Water Heater -Alternator -Battery Charger -Electronic Governor -UL Listed & CSA Approved -209 Total Hours Since New -Dimensions: 76"L x 37"W x 46"H -LOAD BANK TESTED -- $10,500 |
|
|
30 kw Olympian / Ford (Enclosed, 4.2L Ford V6, 138 Hours, Mfg. 2001) Natural Gas/LP Genset
30 KW OLYMPIAN / FORD NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2001 -Model Number: G30F3 -Serial Number: OLY00000ENFS00294 -Standby Rated at 30 kw / 37.5 kva -Currently Setup 120/208 Volt, 3 Phase (104.1 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 4.2L Ford V6 Natural Gas / Propane Engine -Model Number: ESG642I6005E -Serial Number: 01-05-005323 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -FG Wilson 4001E Analog Control Panel -125 Amp 3 Pole ABB Mainline Circuit Breaker -Jacket Water Heater -Alternator -Woodward LCS Electronic Governor -Muffler (Mounted Inside Enclosure) -138 Total Hours Since New -Dimensions: 86"L x 37"W x 61"H -LOAD BANK TESTED -- $9,500 |
|
|
30 kw MTU / GM (Sound-Attenuated, 4.3L GM V6, 157 Hours, Mfg. 2009) Natural Gas/LP Genset
30 KW MTU / GM NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2009 -Model Number: NL30GG6 -Serial Number: MRP0176692-0209 -Standby Rated at 30 kw, 3 Phase or 30 kw, Single Phase -Currently Setup 120/240 Volt, Single Phase (125 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM, 1.0 PF -12 Battery Volts -Powered by a 4.3L GM V6 Natural Gas / Propane Engine -Serial Number: 4P3L50671 -Skid-Mounted -Radiator Cooled -Sound-Attenuated Enclosure -Kassec 1.5 Analog Control Panel -125 Amp 3 Pole Square D Mainline Circuit Breaker -Jacket Water Heater -Alternator -Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed & CSA Approved -157 Total Hours Since New -Generator Dimensions: 111"L x 42"W x 66"H -Dimensions w/ Pallet: 120"L x 44"W x 72"H -LOAD BANK TESTED -- $11,900 |
|
|
35 kw Onan / Ford (Enclosed, 4.2L Ford V6, 1,074 Hours, Mfg. 2002) Natural Gas/LP Genset
35 KW ONAN / FORD NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2002 -Model Number: 35GGFD-3293 -Serial Number: K020442303 -Spec: B -Standby Rated at 35 kw, 3 Phase or 35 kw, Single Phase -Currently Setup 120/240 Volt, Single Phase (145.8 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM, 1.0 PF -12 Battery Volts -Powered by a 4.2L Ford V6 Natural Gas / Propane Engine -Model Number: ESG-642I-6005-A -Serial Number: 02-09-015608 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -Detector Analog Control Panel -175 Amp 2 Pole Square D Mainline Circuit Breaker -Jacket Water Heater -Alternator -Woodward Electronic Governor -Muffler (Mounted Inside Enclosure) -CSA Approved -1,074 Total Hours Since New -Dimensions: 83"L x 41"W x 62"H -LOAD BANK TESTED -- $11,900 |
|
|
35 kw Generac / Ford (Sound-Attenuated, 5.4L Ford V8, 103 Hours, Mfg. 2016) Natural Gas/LP Genset
35 KW GENERAC / FORD NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2016 -Model Number: 1325200 -Serial Number: 3000069890 -Type Code: SG0035AG035.4V18HBLYA -Standby Rated at 35 kw / 35 kva -Setup 120/240 Volt, Single Phase ONLY (145 Amps) -NOT Reconnectable to Other Voltages -4 Wire -60 Hertz, 1800 RPM, 1.0 PF -12 Battery Volts -Powered by a 5.4L Ford V8 Natural Gas / Propane Engine -Skid-Mounted -Radiator Cooled -Sound-Attenuated Enclosure -Generac Digital Control Panel (H-Panel) -175 Amp 3 Pole Eaton Mainline Circuit Breaker -Jacket Water Heater -Alternator -Battery Charger -Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed -103 Total Hours Since New -Dimensions: 95"L x 38"W x 63"H -LOAD BANK TESTED -(7) IDENTICAL UNITS IN STOCK -- $12,500 ea. |
|
|
35 kw Onan / Ford (Open Frame, 4.9L 6 Cyl. Ford, 862 Hours, Mfg. 2000) Natural Gas/LP Genset
35 KW ONAN / FORD NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2000 -Model Number: GGFB-3387978 -Serial Number: A000054144 -Spec: B -Standby Rated at 35 kw, 3 Phase or 23.5 kw, Single Phase -Currently Setup 120/208 Volt, 3 Phase (121.6 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 4.9L Inline 6 Cylinder Ford Natural Gas / Propane Engine -Model Number: CSG-649I-6005-A -Serial Number: 36688-1-04-98 -Skid-Mounted -Radiator Cooled -Open Frame -Detector Analog Control Panel -125 Amp 3 Pole Square D Mainline Circuit Breaker -Jacket Water Heater -Alternator -Woodward TQ-125 Electronic Governor -CSA Approved -862 Total Hours Since New -Dimensions: 83"L x 40"W x 62"H -LOAD BANK TESTED -- $8,500 |
|
|
35 kw Onan / Ford (Sound-Attenuated, 4.2L Ford V6, 211 Hours, Mfg. 2007) Natural Gas/LP Genset
35 KW ONAN / FORD NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2007 -Model Number: GGFD-5786149 -Serial Number: A070011667 -Spec: G -Standby Rated at 35 kw, 3 Phase or 23.5 kw, Single Phase -Currently Setup 277/480 Volt, 3 Phase (52.6 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 4.2L Ford V6 Natural Gas / Propane Engine -Model Number: ESG642 -Serial Number: 07ZK63552 -Skid-Mounted -Radiator Cooled -QuietSite Sound-Attenuated Enclosure -PowerCommand 2100 Digital Control Panel -70 Amp 3 Pole Square D Mainline Circuit Breaker -Jacket Water Heater -Alternator -Battery Charger -Woodward Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed & CSA Approved -211 Total Hours Since New -Dimensions: 103"L x 41"W x 78"H -LOAD BANK TESTED -- $12,500 |
|
|
35 kw Onan / Ford (Enclosed, 4.2L Ford V6, 460 Hours, Mfg. 2005) Natural Gas/LP Genset
35 KW ONAN / FORD NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2005 -Model Number: GGFD-5703254 -Serial Number: A050739641 -Spec: E -Standby Rated at 35 kw, 3 Phase or 23.5 kw, Single Phase -Currently Setup 120/208 Volt, 3 Phase (121.4 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 4.2L Ford V6 Natural Gas / Propane Engine -Model Number: ESG642 -Serial Number: 05ZK38788 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -PowerCommand 2100 Digital Control Panel -100 Amp 3 Pole Square D Mainline Circuit Breaker -Jacket Water Heater -Alternator -Battery Charger -Woodward L-Series Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed & CSA Approved -460 Total Hours Since New -Dimensions: 83"L x 41"W x 60"H -LOAD BANK TESTED -- $11,900 |
|
|
35 kw Onan / GM (Open Frame, 5.0L GM V8, 286 Hours, Mfg. 2010) Natural Gas/LP Genset
35 KW ONAN / GM NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2010 -Model Number: GGPA-6161499 -Serial Number: K100172236 -Spec: A -Standby Rated at 35 kw, 3 Phase or 23.5 kw, Single Phase -Currently Setup 120/208 Volt, 3 Phase (121.4 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM, 0.8 PF -12 Battery Volts -Powered by a 5.0L GM V8 Natural Gas / Propane Engine -Model Number: GM-5.0L -Serial Number: 5P0L11596 -Skid-Mounted -Radiator Cooled -Open Frame -PowerCommand 2100 Digital Control Panel -30 Amp & 100 Amp 3 Pole Square D Circuit Breakers -Jacket Water Heater -Alternator -Woodward L-Series Electronic Governor -Muffler (Shipped Loose) -UL Listed & CSA Approved -286 Total Hours Since New -Dimensions: 77"L x 33"W x 49"H -LOAD BANK TESTED -- $9,500 |
|
|
39 kw Kohler / GM (Enclosed, 4.3L GM V6, 155 Hours, Mfg. 2015) Natural Gas/LP Genset
39 KW KOHLER / GM NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2015 -Generator End Model Number: 4P5 -Generator Set Model Number: 38RCL -Generator Set Serial Number: SGM32CXZR -Generator Set Spec: GM84992-GA1 -Standby Rated at 39 kw / 48.8 kva -Setup 120/208 Volt, 3 Phase (135 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM, 0.8 PF -12 Battery Volts -Powered by a 4.3L GM V6 Natural Gas / Propane Engine -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -Control Panel -Mainline Circuit Breaker -Jacket Water Heater -Alternator -Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed -155 Hours Since New -- COMING IN! |
|
|
40 kw Olympian / Ford (Sound-Attenuated, 5.4L Ford V8, 17 Hours, Mfg. 2016) Natural Gas/LP Genset
40 KW OLYMPIAN / FORD NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2016 -Model Number: G40LG2 -Serial Number: GXB04111-OLY00000 -Type Code: LG0040GG035.4N18HPSYA -Standby Rated at 40 kw / 50 kva -Upsize Alt: 50 kw -Currently Setup 120/208 Volt, 3 Phase (138 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 5.4L Ford V8 Natural Gas / Propane Engine -Serial Number: E172A 081215 3420474 -Skid-Mounted -Radiator Cooled -Sound-Attenuated Enclosure -Generac Digital Control Panel (H-Panel) -150 Amp 3 Pole Eaton Mainline Circuit Breaker -Jacket Water Heater -Alternator -Battery Charger -Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed -17 Total Hours Since New -Dimensions: 113"L x 38"W x 50"H -LOAD BANK TESTED -- SOLD |
|
|
45 kw Kohler / GM (Enclosed, 5.0L GM V8, 600 Hours, Mfg. 2004) Natural Gas/LP Genset
45 KW KOHLER / GM NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2004 -Generator End Model Number: 4P8 -Generator Set Model Number: 50RZGB -Generator Set Serial Number: 2002802 -Generator Set Spec: GM21302-GA1 -Standby Rated at 45 kw, Single Phase or 45 kw, 3 Phase (NG or LP) -Currently Setup 277/480 Volt, 3 Phase -12 Lead Reconnectable -60 Hertz, 1800 RPM, 0.8 PF -12 Battery Volts -Powered by a 5.0L GM V8 Natural Gas / Propane Engine -Engine Model Number: GM-5.0L -Engine Serial Number: 5.0L-005796 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -Kohler Decision-Maker 3+ 16 Light Analog Control Panel -100 Amp 3 Pole Airpax Circuit Breaker -Jacket Water Heater -Alternator -Battery Charger -Woodward L-Series Electronic Governor -Muffler (Mounted Outside Enclosure) -UL Listed -600 Total Hours Since New -Dimensions: 88"L x 42"W x 70"H -LOAD BANK TESTED -- $12,500 |
|
|
47 kw Onan / Ford (Enclosed, 4.2L Ford V6, 337 Hours, Mfg. 2002) Natural Gas/LP Genset
47 KW ONAN / FORD NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2002 -Model Number: GGFE-5570147 -Serial Number: J020424786 -Spec: B -Standby Rated at 47 kw, 3 Phase or 31.5 kw, Single Phase -Currently Setup 120/208 Volt, 3 Phase (163.1 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM, 0.8 PF -12 Battery Volts -Powered by a 4.2L Ford V6 Natural Gas / Propane Engine -Model Number: ESG642I-6005-A -Serial Number: 02-08-014992 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -Detector Analog Control Panel -200 Amp 3 Pole Merlin Gerin Mainline Circuit Breaker -Jacket Water Heater -Alternator -Woodward Electronic Governor -Muffler (Mounted Inside Enclosure) -CSA Approved -337 Total Hours Since New -Dimensions: 84"L x 41"W x 61"H -LOAD BANK TESTED -- $13,500 |
|
|
50 kw Generac / Ford (Sound-Attenuated, 5.4L Ford V8, 226 Hours, Mfg. 2014) Natural Gas/LP Genset
50 KW GENERAC / FORD NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2014 -Model Number: 17421970100 -Serial Number: 9073793 -Type Code: SG0050AG035.4V18HPLYA -Standby Rated at 50 kw / 50 kva -Setup 120/240 Volt, Single Phase ONLY (208.3 Amps) -NOT Reconnectable to Other Voltages -4 Wire -60 Hertz, 1800 RPM, 1.0 PF -12 Battery Volts -Powered by a 5.4L Ford V8 Natural Gas / Propane Engine -Serial Number: E172A1305141330517 -Skid-Mounted -Radiator Cooled -Sound-Attenuated Enclosure -Generac Digital Control Panel (H-Panel) -200 Amp 3 Pole Eaton Mainline Circuit Breaker -Jacket Water Heater -Alternator -Battery Charger -Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed -226 Total Hours Since New -Dimensions: 95"L x 38"W x 62"H -LOAD BANK TESTED -- $14,900 |
|
|
50 kw Onan / GM (Sound-Attenuated, 5.0L GM V8, 153 Hours, Mfg. 2012) Natural Gas/LP Genset
50 KW ONAN / GM NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2012 -Model Number: GGPC-10462834 -Serial Number: B120303659 -Spec: A -Standby Rated -50 kw, 3 Phase (Propane) -45 kw, 3 Phase (Natural Gas) -30.2 kw, Single Phase (Natural Gas) -Currently Setup 120/208 Volt, 3 Phase (156.1 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM, 0.8 PF -12 Battery Volts -Powered by a 5.0L GM V8 Natural Gas / Propane Engine -Model Number: GM-5.0L -Serial Number: 5.0L13847 -Skid-Mounted -Radiator Cooled -Sound-Attenuated Enclosure -PowerCommand 2100 Digital Control Panel -150 Amp 3 Pole Square D Mainline Circuit Breaker -Jacket Water Heater -Alternator -Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed & CSA Approved -153 Total Hours Since New -Video Available -Dimensions: 86"L x 41"W x 78"H -LOAD BANK TESTED -- $15,500 |
|
|
50 kw Generac / Ford (Open Frame, 6.8L Ford V10, 1.6 Hours, New Surplus, Mfg. 2010) Natural Gas/LP Genset
50 KW GENERAC / FORD NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2010 -Model Number: 11993670100 -Serial Number: 2106459 -Type Code: SG0050AG036.8V18HPNLA -Standby Rated at 50 kw / 50 kva -Setup 120/240 Volt, Single Phase ONLY (208.3 Amps) -NOT Reconnectable to Other Voltages -4 Wire -60 Hertz, 1800 RPM, 1.0 PF -12 Battery Volts -Powered by a 6.8L Ford V10 Natural Gas / Propane Engine -Model Number: WSG1068 -Serial Number: E171A 170210 0482251 -Skid-Mounted -Radiator Cooled -Open Frame -Generac Digital Control Panel (H-Panel) -200 Amp 3 Pole Siemens Mainline Circuit Breaker -Jacket Water Heater -Alternator -Battery Charger -Electronic Governor -Muffler (Shipped Loose) -1.6 Hours (New Surplus) -Generator Dimensions: 99"L x 40"W x 73"H -Dimensions Including Pallet: 112"L x 36"W x 79"H -LOAD BANK TESTED -- $12,500 |
|
|
55 kw Katolight / Hercules (Enclosed, 6 Cyl. Hercules, 415 Hours) Natural Gas/LP Genset
55 KW KATOLIGHT / HERCULES NATURAL GAS OR PROPANE GENERATOR
-Model Number: L55FGH4 -Serial Number: AD161521SRF C-40245 -Standby Rated at 55 kw / 55 kva -Currently Setup 120/240 Volt, Single Phase (229 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by an Inline 6 Cylinder Hercules Natural Gas / Propane Engine -Model Number: G3400 -Serial Number: JS3336141 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -Kassec 1.5 Analog Control Panel -200 Amp 3 Pole GE Mainline Circuit Breaker -Jacket Water Heater -Alternator -Mechanical Governor -Muffler (Mounted Inside Enclosure) -415 Total Hours Since New -Dimensions: 90"L x 40"W x 75"H -LOAD BANK TESTED -- $10,900 |
|
|
60 kw Kohler / GM (Enclosed, 5.7L GM V8, 320 Hours, Mfg. 2012) Natural Gas/LP Genset
60 KW KOHLER / GM NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2012 -Generator End Model Number: 4P10X -Generator Set Model Number: 60REZGB -Generator Set Serial Number: SGM322MHX -Generator Set Spec: GM79037-GA1 -Standby Rated -64 kw (LP) or 60 kw (NG) @ 480V, 3 Phase -63 kw (LP) or 60 kw (NG) @ 208V or 240V, 3 Phase -61 kw (LP) or 59 kw (NG) @ 240V, Single Phase -Panel Set @ 60 kw (Needs Reprogramming to Achieve Max kw and / or w/ Voltage Change) -Currently Setup 277/480 Volt, 3 Phase -12 Lead Reconnectable (w/ Reprogramming) -60 Hertz, 1800 RPM, 0.8 PF -12 Battery Volts -Powered by a 5.7L GM V8 Natural Gas / Propane Engine -Engine Model Number: GM-5.7L -Engine Serial Number: 5.7L24634 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -Kohler Decision-Maker 3000 Digital Control Panel -100 Amp 3 Pole Square D Mainline Circuit Breaker -Jacket Water Heater -Alternator -Battery Charger -Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed -320 Total Hours Since New -Dimensions: 102"L x 43"W x 61"H -LOAD BANK TESTED -- $15,500 |
|
|
60 kw Onan / Ford (Sound-Attenuated, 6.8L Ford V10, 291 Hours, Mfg. 2014) Natural Gas/LP Genset
60 KW ONAN / FORD NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2014 -Model Number: GGHE-1401646 -Serial Number: C140651974 -Spec: M -Standby Rated at 60 kw, 3 Phase or 60 kw, Single Phase (Natural Gas or Propane) -Currently Setup 120/240 Volt, Single Phase (250 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM, 1.0 PF -12 Battery Volts -Powered by a 6.8L Ford V10 Natural Gas / Propane Engine -Model Number: WSG-1068 -Serial Number: E172A 200114 0200088 -Skid-Mounted -Radiator Cooled -Sound-Attenuated Enclosure -PowerCommand 2100 Digital Control Panel -200 Amp 2 Pole Square D Mainline Circuit Breaker -Jacket Water Heater -Alternator -Battery Charger -Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed & CSA Approved -291 Total Hours Since New -Dimensions: 103"L x 41"W x 78"H -LOAD BANK TESTED -- $16,500 |
|
|
60 kw Katolight / GM (Enclosed, 5.7L GM V8, 650 Hours, Mfg. 2003) Natural Gas/LP Genset
60 KW KATOLIGHT / GM NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2003 -Generator Model Number: N60FGG4 -Generator Serial Number: 648300 88057-0303 -Standby Rated -Setup 120/240 Volt, Single Phase (250 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM, 1.0 PF -12 Battery Volts -Powered by a 5.7L GM V8 Natural Gas / Propane Engine -Model Number: GM-5.7L -Serial Number: 5.7L-7202 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -Katolight KDGC-500 Digital Control Panel -Mainline Circuit Breaker -Jacket Water Heater -Alternator -Battery Charger -Electronic Governor -Muffler (Mounted Inside Enclosure) -CSA Approved -650 Hours Since New -Dimensions: 80"L x 40"W x 54"H -- PLEASE CALL FOR PRICING! |
|
|
65 kw Onan / Ford (Sound-Attenuated, 7.5L Ford 460 V8, 1,596 Hours, Mfg. 1998) Natural Gas/LP Genset
65 KW ONAN / FORD NATURAL GAS OR PROPANE GENERATOR
-Mfg. 1998 -Model Number: 65GGHB -Serial Number: A980673066 -Spec: 92795A -Standby Rated at 65 kw, 3 Phase or 43.6 kw, Single Phase -Currently Setup 120/240 Volt, Single Phase (182 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 7.5L Ford 460 V8 Natural Gas / Propane Engine -Model Number: LSG-875I-6005-A -Serial Number: 24045 E-14-RH -Skid-Mounted -Radiator Cooled -Sound-Attenuated Enclosure -Belimo Powered Louvers -Detector Analog Control Panel -CJ400N 3 Pole Merlin Gerin Compact Mainline Circuit Breaker (w/ 300 Amp Plug) -Jacket Water Heater -Alternator -Woodward TQ125 Electronic Governor -1,596 Total Hours Since New -Dimensions: 127"L x 56"W x 74"H -LOAD BANK TESTED -- $14,900 |
|
|
65 kw Onan / Ford (Enclosed, 7.5L Ford 460 V8, 922 Hours, Mfg. 2000) Natural Gas/LP Genset
65 KW ONAN / FORD NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2000 -Model Number: GGHB-4477798 -Serial Number: C000080666 -Spec: B -Standby Rated at 65 kw, 3 Phase or 43.6 kw, Single Phase -Currently Setup 277/480 Volt, 3 Phase (97.8 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 7.5L Ford 460 V8 Natural Gas / Propane Engine -Model Number: LSG-875I-6005-A -Serial Number: 16333-1-04-98 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -Detector Analog Control Panel -125 Amp 3 Pole Merlin Gerin Mainline Circuit Breaker -Jacket Water Heater -Alternator -Woodward TQ-125 Electronic Governor -Muffler (Mounted Inside Enclosure) -CSA Approved -922 Total Hours Since New -Dimensions: 83"L x 41"W x 60"H -LOAD BANK TESTED -- $14,900 |
|
|
75 kw Onan / Ford (Sound-Attenuated, 6.8L Ford V10, 584 Hours, Mfg. 2006) Natural Gas/LP Genset
75 KW ONAN / FORD NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2006 -Model Number: GGHF-5757308 -Serial Number: D060909054 -Spec: E -Standby Rated at 75 kw, 3 Phase or 50.3 kw, Single Phase -Currently Setup 120/240 Volt, 3 Phase (225.5 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM, 0.8 PF -12 Battery Volts -Powered by a 6.8L Ford V10 Natural Gas / Propane Engine -Model Number: WSG1068 -Serial Number: 06WS54758 -Skid-Mounted -Radiator Cooled -Quiet-Site Sound-Attenuated Enclosure -PowerCommand 2100 Digital Control Panel -160/400 Amp 3 Pole Adjustable Merlin Gerin Mainline Circuit Breaker -Jacket Water Heater -Alternator -Woodward Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed & CSA Approved -584 Total Hours Since New -Dimensions: 103"L x 41"W x 78"H -LOAD BANK TESTED -- SOLD |
|
|
80 kw Kohler / Ford (Open Frame, 7.5L Ford 460 V8, 503 Hours) Natural Gas/LP Genset
80 KW KOHLER / FORD NATURAL GAS OR PROPANE GENERATOR
-Model Number: 80RZ72 -Serial Number: 350693 -Spec: PA-187341-72N -Standby Rated at 80 kw / 100 kva -Setup 277/480 Volt, 3 Phase (120 Amps) -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 7.5L Ford 460 V8 Turbocharged Natural Gas / Propane Engine -Model Number: LSG-875I-6005-A -Serial Number: 14026 T-30-RL -Skid-Mounted -Radiator Cooled -Open Frame -Kohler Decision-Maker 3+ 16 Light Analog Control Panel -Jacket Water Heater -Alternator -Electronic Governor -Muffler (Shipped Loose) -503 Total Hours Since New -Dimensions: 91"L x 35"W x 52"H -- PLEASE CALL FOR PRICING! |
|
|
85 kw Onan / Ford (Sound-Attenuated, 6.8L Ford, 553 Hours, Mfg. 2007) Natural Gas/LP Genset
85 KW ONAN / FORD NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2007 -Model Number: GGHG-5864559 -Serial Number: F070070731 -Spec: G -Standby Rated at 85 kw, 3 Phase or 57 kw, Single Phase -Currently Setup 277/480 Volt, 3 Phase (127.8 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM, 0.8 PF -12 Battery Volts -Powered by a 6.8L Ford V10 Turbocharged Natural Gas / Propane Engine -Model Number: WSG1068 -Serial Number: 07WS65741 -Skid-Mounted -Radiator Cooled -Sound-Attenuated Enclosure -PowerCommand 2100 Digital Control Panel -150 Amp 3 Pole Square D Mainline Circuit Breaker -Jacket Water Heater -Alternator -Woodward Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed & CSA Approved -553 Total Hours Since New -Dimensions: 143"L x 41"W x 70"H -LOAD BANK TESTED -- $21,500 |
|
|
97 kw Baldor / GM (Enclosed, 8.1L GM V8, 524 Hours, Mfg. 2003) Natural Gas/LP Genset
97 KW BALDOR / GM NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2003 -Model Number: GLC-100 -Serial Number: P0309230001 -Spec: 10.95100-G14 -Rated 97 kw, Propane or 84 kw, Natural Gas -Setup 120/240 Volt, Single Phase ONLY -NOT Reconnectable to Other Voltages -4 Wire -60 Hertz, 1800 RPM, 1.0 PF -12 Battery Volts -Powered by an 8.1L GM V8 Natural Gas / Propane Engine -Model Number: GM-8.1L -Serial Number: 8.1L-07448 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -Thomson Technology MEC 20 Digital Control Panel -600 Amp 3 Pole Cutler Hammer LG Mainline Circuit Breaker (Set for 500 Amp Trip) -Jacket Water Heater -Alternator -Battery Charger -Woodward L-Series Electronic Governor -Muffler (Mounted Outside Enclosure) -524 Total Hours Since New -Dimensions: 90"L x 45"W x 88"H -Weight: 4,000 lbs. -LOAD BANK TESTED -(2) IN STOCK -- PLEASE CALL FOR PRICING! |
|
|
98 kw Kohler / GM (Enclosed, 5.7L GM V8, 141 Hours, Mfg. 2012) Natural Gas/LP Genset
98 KW KOHLER / GM NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2012 -Generator End Model Number: 4R9X -Generator Set Model Number: 100REZGD -Generator Set Serial Number: 3061850 -Generator Set Spec: GM81112-GA7 -Standby Rated at 98 kw, 3 Phase or 77 kw, Single Phase (NG or LP) -Currently Setup 277/480 Volt, 3 Phase -12 Lead Reconnectable (w/ Reprogramming) -60 Hertz, 1800 RPM, 0.8 PF -12 Battery Volts -Powered by a 5.7L GM V8 Turbocharged Natural Gas / Propane Engine -Engine Model Number: GM-5.7L -Engine Serial Number: 5.7L23704 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -Kohler Decision-Maker 3000 Digital Control Panel -100 Amp 3 Pole Square D Mainline Circuit Breaker -Jacket Water Heater -Alternator -Battery Charger -Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed -141 Total Hours Since New -Video Available -Dimensions: 139"L x 45"W x 67"H -LOAD BANK TESTED -- $23,500 |
|
|
100 kw Kohler / Ford (Open Frame, 7.5L Ford 460 V8, 1,271 Hours) Natural Gas/LP Genset
100 KW KOHLER / FORD NATURAL GAS OR PROPANE GENERATOR
-Model Number: 100RZ272 -Serial Number: 273673 -Spec: 187435-72N -Standby Rated at 100 kw, 3 Phase or 80 kw, Single Phase -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 7.5L Ford 460 V8 Turbocharged Natural Gas / Propane Engine -Model Number: LSG-875I-6005-A -Serial Number: 13927 T-17-RM -Skid-Mounted -Radiator Cooled -Open Frame -Kohler Decision-Maker 3+ 16 Light Analog Control Panel -Westinghouse Mainline Circuit Breaker -Jacket Water Heater -Alternator -Barber Colman Electronic Governor -1,271 Total Hours Since New -Dimensions: 91"L x 35"W x 50"H -- PLEASE CALL FOR PRICING! |
|
|
100 kw Onan / Ford (Enclosed, 6.8L Ford V10, 773 Hours, Mfg. 2005) Natural Gas/LP Genset
100 KW ONAN / FORD NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2005 -Model Number: GGHH-5705683 -Serial Number: B050747971 -Spec: E -Standby Rated at 100 kw, 3 Phase or 100 kw, Single Phase -Currently Setup 120/240 Volt, Single Phase (416.7 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM, 1.0 PF -12 Battery Volts -Powered by a 6.8L Ford V10 Turbocharged Natural Gas / Propane Engine -Model Number: WSG1068 -Serial Number: 05ZS38959 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -PowerCommand 2100 Digital Control Panel -400 Amp 2 Pole Square D Mainline Circuit Breaker -Jacket Water Heater -Alternator -Woodward Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed & CSA Approved -773 Total Hours Since New -Dimensions: 105"L x 41"W x 62"H -LOAD BANK TESTED -- $22,500 |
|
|
100 kw Onan / Ford (Enclosed, 7.5L Ford 460 V8, 762 Hours, Mfg. 2000) Natural Gas/LP Genset
100 KW ONAN / FORD NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2000 -Model Number: GGHD-4479154 -Serial Number: D000090880 -Spec: B -Standby Rated -100 kw, 3 Phase or 67 kw, Single Phase (NG) -80 kw, 3 Phase or 53 kw, Single Phase (LP) -Currently Setup 120/208 Volt, 3 Phase (347 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM, 0.8 PF -12 Battery Volts -Powered by a 7.5L Ford 460 V8 Turbocharged Natural Gas / Propane Engine -Serial Number: 16553-1-04-98 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -Detector Analog Control Panel -400 Amp 3 Pole Square D Mainline Circuit Breaker -Jacket Water Heater -Alternator -Woodward TQ 125 Electronic Governor -Muffler (Mounted Inside Enclosure) -CSA Approved -762 Total Hours Since New -Dimensions: 106"L x 41"W x 62"H -LOAD BANK TESTED -- $19,500 |
|
|
100 kw Katolight / GM (Sound-Attenuated, 8.1L GM V8, 367 Hours, Mfg. 2005) Natural Gas/LP Genset
100 KW KATOLIGHT / GM NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2005 -Marathon Generator End -Generator Set Model Number: N100FPG4 -Generator Set Serial Number: 105053-0205 -Standby Rated -Currently Setup 120/208 Volt, 3 Phase (347 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM, 0.8 PF -12 Battery Volts -Powered by an 8.1L GM V8 Natural Gas / Propane Engine -Engine Model Number: GM-8.1L -Engine Serial Number: 8P1L09828 -Skid-Mounted -Radiator Cooled -Sound-Attenuated Enclosure -KDGC-2001 Digital Control Panel -350 Amp 3 Pole GE Mainline Circuit Breaker -Jacket Water Heater -Alternator -Battery Charger -Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed -367 Total Hours Since New -Dimensions: 110"L x 47"W x 75"H -LOAD BANK TESTED -- $22,000 |
|
|
125 kw Kohler / GM (Sound-Attenuated, 8.1L GM V8, 467 Hours, Mfg. 2008) Natural Gas/LP Genset
125 KW KOHLER / GM NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2008 -Generator End Model Number: 4S11 -Generator Set Model Number: 125RZG -Generator Set Serial Number: 2193933 -Generator Set Spec: GM34464-GA1 -Standby Rated -125 kw, 3 Phase or 95 kw, Single Phase (NG) -105 kw, 3 Phase or 95 kw, Single Phase (LP) -Currently Setup 120/208 Volt, 3 Phase (434 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM, 0.8 PF -12 Battery Volts -Powered by an 8.1L GM V8 Turbocharged Natural Gas / Propane Engine -Engine Model Number: GM-8.1L -Engine Serial Number: 8P1L17205 -Skid-Mounted -Radiator Cooled -Sound-Attenuated Enclosure -Kohler Decision-Maker 3+ 16 Light Analog Control Panel -600 Amp 3 Pole Square D Mainline Circuit Breaker -Jacket Water Heater -Alternator -Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed -467 Total Hours Since New -Dimensions: 124"L x 42"W x 80"H -LOAD BANK TESTED -- $24,500 |
|
|
125 kw Onan / GM (Open Frame, 8.1L GM V8, 355 Hours, Mfg. 2010) Natural Gas/LP Genset
125 KW ONAN / GM NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2010 -Model Number: GGLA-6209521 -Serial Number: L100175396 -Spec: H -Standby Rated at 125 kw, Single Phase (Natural Gas) or 115 kw, Single Phase (Propane) -Setup 120/240 Volt, Single Phase ONLY (520.8 Amps) -NOT Reconnectable to Other Voltages -4 Wire -60 Hertz, 1800 RPM, 1.0 PF -12 Battery Volts -Powered by an 8.1L GM V8 Turbocharged Natural / Propane Gas Engine -Model Number: GM-8.1L -Serial Number: 8.1L24789 -Skid-Mounted -Radiator Cooled -Open Frame -PowerCommand 2100 Digital Control Panel -400 Amp 2 Pole Square D Mainline Circuit Breaker -Jacket Water Heater -Alternator -Electronic Governor -Exhaust Flex Pipe (Shipped Loose) -UL Listed & CSA Approved -355 Total Hours Since New -Dimensions: 106"L x 41"W x 70"H -LOAD BANK TESTED -(2) IN STOCK -- $22,500 ea. |
|
|
130 kw Kohler / GM (Partially Sound-Attenuated, 8.1L GM V8, 619 Hours, Mfg. 2002) Natural Gas/LP Genset
130 KW KOHLER / GM NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2002 -Generator End Model Number: 4S13 -Generator Set Model Number: 125RZG -Generator Set Serial Number: 0747310 -Generator Set Spec: ES-64449-GA -Standby Rated -130 kw, 3 Phase or 100 kw, Single Phase (NG) -110 kw, 3 Phase or 100 kw, Single Phase (LP) -Currently Setup 277/480 Volt, 3 Phase (195 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM, 0.8 PF -12 Battery Volts -Powered by an 8.1L GM V8 Turbocharged Natural Gas / Propane Engine -Engine Model Number: GM-8.1L -Engine Serial Number: 8.1L-06497 -Skid-Mounted -Radiator Cooled -Partially Sound-Attenuated Enclosure -Kohler Decision-Maker 3+ 16 Light Analog Control Panel -40 Amp & 125 Amp 3 Pole Square D Mainline Circuit Breakers -Jacket Water Heater -Alternator -Battery Charger -Electronic Governor -Muffler (Mounted Inside Enclosure) -619 Total Hours Since New -Dimensions: 95"L x 43"W x 80"H -LOAD BANK TESTED -- $24,500 |
|
|
130 kw Kohler / GM (Open Frame, 8.1L GM V8, 751 Hours, Mfg. 2003) Natural Gas/LP Genset
130 KW KOHLER / GM NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2003 -Generator End Model Number: 4S13 -Generator Set Model Number: 125RZG -Generator Set Serial Number: 0757789 -Generator Set Spec: GM25339-GA1 -Standby Rated -130 kw, 3 Phase or 100 kw, Single Phase (NG) -110 kw, 3 Phase or 100 kw, Single Phase (LP) -Currently Setup 277/480 Volt, 3 Phase (195 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by an 8.1L GM V8 Turbocharged Natural Gas / Propane Engine -Engine Model Number: GM-8.1L -Engine Serial Number: 8.1L-07214 -Skid-Mounted -Radiator Cooled -Open Frame -Kohler Decision-Maker 3+ 16 Light Analog Control Panel -(2) 225 Amp 3 Pole Square D Circuit Breakers -Jacket Water Heater -Alternator -Electronic Governor -751 Total Hours Since New -Dimensions: 96"L x 35"W x 55"H -LOAD BANK TESTED -- $22,000 |
|
|
150 kw Kohler / 50 Series Detroit (Open Frame, 8.5L 4 Cyl. Detroit, 1,092 Hours, Mfg. 2003) Natural Gas/LP Genset
150 KW KOHLER / 50 SERIES DETROIT NATURAL GAS GENERATOR
-Mfg. 2003 -Generator End Model Number: 4S13 -Generator Set Model Number: 150RZD -Generator Set Serial Number: 0758967 -Standby Rated at 150 kw / 188 kva -Currently Setup 120/208 Volt, 3 Phase (520 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -24 Battery Volts -Powered by an 8.5L 4 Cylinder Turbocharged 50 Series Detroit Natural Gas Engine -Unit Number: 04R0042249 -S.O. Number: 851891 -Model Number: 6043TKG5 -Spec: A 343044 -Rated 260 HP @ 1800 RPM -Skid-Mounted -Radiator Cooled -Open Frame -Kohler Decision-Maker 3+ 16 Light Analog Control Panel -600 Amp 3 Pole Square D Mainline Circuit Breaker -Jacket Water Heater -Alternator -Battery Charger -Electronic Governor -Exhaust Flex Pipe (Mounted) -1,092 Total Hours Since New -Video Available -Dimensions: 115"L x 51"W x 80"H -LOAD BANK TESTED -- $25,000 |
|
|
150 kw MTU / Detroit (Enclosed, 50 Series Detroit, 1,665 Hours, Mfg. 2004) Natural Gas/LP Genset
150 KW MTU / DETROIT NATURAL GAS GENERATOR
-Mfg. 2004 -Generator End Model Number: 4S13 -Generator Set Model Number: 150GS -Generator Set Serial Number: 2022756 -Generator Set Spec: GM16894-GA1S -Standby Rated at 150 kw / 188 kva -Currently Setup 277/480 Volt, 3 Phase (226 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -24 Battery Volts -Powered by an 8.5L 4 Cylinder Turbocharged 50 Series Detroit Natural Gas Engine -For Natural Gas Use ONLY -Engine Serial Number: 04R0046605 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -Kohler Decision-Maker 550 Digital Control Panel -200 Amp 3 Pole Square D Mainline Circuit Breaker -Jacket Water Heater -Alternator -Battery Charger -Electronic Governor -Muffler (Mounted Outside Enclosure) -1,665 Total Hours Since New -Dimensions: 117"L x 51"W x 104"H -LOAD BANK TESTED -- $29,000 |
|
|
150 kw Onan / GM (Enclosed, 8.1L GM V8, 409 Hours, Mfg. 2008) Natural Gas/LP Genset
150 KW ONAN / GM NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2008 -Model Number: GGLB-7521785 -Serial Number: L080224294 -Spec: E -Standby Rated -150 kw, 3 Phase (Natural Gas) -140 kw, 3 Phase (Propane) -100.5 kw, Single Phase (Natural Gas) -Currently Setup 277/480 Volt, 3 Phase -12 Lead Reconnectable -60 Hertz, 1800 RPM, 0.8 PF -12 Battery Volts -Powered by an 8.1L GM V8 Turbocharged Natural / Propane Gas Engine -Model Number: GM-8.1L -Serial Number: 8P1L19676 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -PowerCommand 2100 Digital Control Panel -225 Amp Square D Mainline Circuit Breaker -Jacket Water Heater -Alternator -Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed & CSA Approved -409 Total Hours Since New -Video Available -Dimensions: 111"L x 41"W x 71"H -LOAD BANK TESTED -- PLEASE CALL FOR PRICING! |
|
|
150 kw Onan / GM (Sound-Attenuated, 8.1L GM V8, 271 Hours, Mfg. 2009) Natural Gas/LP Genset
150 KW ONAN / GM NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2009 -Model Number: GGLB-545907 -Serial Number: F090012083 -Spec: G -Standby Rated at 150 kw, Natural Gas or 140 kw, Propane -Setup 120/240 Volt, Single Phase ONLY (583.3 Amps) -NOT Reconnectable to Other Voltages -4 Wire -60 Hertz, 1800 RPM, 1.0 PF -12 Battery Volts -Powered by an 8.1L GM V8 Turbocharged Natural / Propane Gas Engine -Model Number: GM-8.1L -Serial Number: 8.1L20850 -Skid-Mounted -Radiator Cooled -Sound-Attenuated Enclosure -70 kw Simplex Load Bank (Attached) -PowerCommand 2100 Digital Control Panel -400 Amp 3 Pole Square D Mainline Circuit Breaker -300 Amp Breaker (for Load Bank) -Jacket Water Heater -Alternator -Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed & CSA Approved -271 Total Hours Since New -Dimensions: 128"L x 60"W x 71"H -LOAD BANK TESTED -- PLEASE CALL FOR PRICING! |
|
|
150 kw Onan / GM (Sound-Attenuated, 8.1L GM V8, 453 Hours, Mfg. 2011) Natural Gas/LP Genset
150 KW ONAN / GM NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2011 -Model Number: GGLB-6813682 -Serial Number: B110193985 -Spec: J -Standby Rated at 150 kw, Natural Gas or 140 kw, Propane -Setup 120/240 Volt, Single Phase ONLY (583.3 Amps) -NOT Reconnectable to Other Voltages -4 Wire -60 Hertz, 1800 RPM, 1.0 PF -12 Battery Volts -Powered by an 8.1L GM V8 Turbocharged Natural / Propane Gas Engine -Model Number: GM-8.1L -Serial Number: 8.1L24905 -Skid-Mounted -Radiator Cooled -Sound-Attenuated Enclosure -PowerCommand 2100 Digital Control Panel -150 Amp & 800 Amp 3 Pole Square D Circuit Breakers (800 Amp is Adjustable & Set at 672 Amps) -Jacket Water Heater -Alternator -Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed & CSA Approved -453 Total Hours Since New -Dimensions: 150"L x 61"W x 70"H -LOAD BANK TESTED -(4) IN STOCK -- $29,500 ea. |
|
|
200 kw Kohler / Detroit (Enclosed, 12.7L 6 Cyl. Detroit, 1,021 Hours, Mfg. 2002) Natural Gas/LP Genset
200 KW KOHLER / DETROIT NATURAL GAS GENERATOR
-Mfg. 2002 -Generator End Model Number: 4UA9 -Generator Set Model Number: 200RZD -Generator Set Serial Number: 0746547 -Generator Set Spec: GM16896-GA1 -Standby Rated at 200 kw / 250 kva -Setup 277/480 Volt, 3 Phase (301 Amps) -60 Hertz, 1800 RPM, 0.8 PF -24 Battery Volts -Powered by a 12.7L Inline 6 Cylinder Turbocharged 60 Series Detroit Natural Gas Engine -Unit Number: 06R0715390 -S.O. Number: 851892 -Model Number: 6063TKG5 -Spec: A 343333 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -Kohler Decision-Maker 3+ 16 Light Analog Control Panel -Mainline Circuit Breaker -Jacket Water Heater -Alternator -Electronic Governor -Muffler (Shipped Loose) -1,021 Hours Since New -- COMING IN! |
|
|
250 kw Cummins / Onan (Open Frame, 19L 6 Cyl. Cummins, 774 Hours, Mfg. 2009) Natural Gas/LP Genset
250 KW CUMMINS / ONAN NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2009 -Model Number: 250GFEA -Serial Number: KM09G043901 -Currently Setup 277/480 Volt, 3 Phase -12 Lead Reconnectable -60 Hertz, 1800 RPM, 0.8 PF -24 Battery Volts -Powered by a 19L Inline 6 Cylinder Turbocharged Cummins Natural Gas or Propane Engine -Setup & Tuned for Natural Gas Use -Model Number: GTA19G1 -Engine Number: 25344063 -Compression Ratio: 8.5:1 -Rated 446 HP @ 1800 RPM -Skid-Mounted -Radiator Cooled -Open Frame -PowerCommand 2100 Digital Control Panel -160/400 Amp 3 Pole Adjustable Merlin Gerin Mainline Circuit Breaker -Jacket Water Heater -Alternator -Battery Charger -Woodward Electronic Governor -Altronic Ignition System -Muffler Assembly (Shipped Loose) -CSA Approved -774 Total Hours Since New -Video Available -Generator Dimensions: 143"L x 68"W x 82"H -Muffler Assembly Dimensions: 90"L x 64"W x 36"H -- PLEASE CALL FOR PRICING! |
|
|
332 kw Baldor / Doosan (Sound-Attenuated, 18.3L 10 Cyl. Doosan, 427 Hours, Mfg. 2009) Natural Gas/LP Genset
332 KW BALDOR / DOOSAN NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2009 -Model Number: IGLC350-2N -Serial Number: P1102090002 -Spec: 10.N2350-G4 -Standby Rated -332 kw, 3 Phase or 200 kw, Single Phase (NG) -220 kw, 3 Phase or 200 kw, Single Phase (LP) -Currently Setup 120/240 Volt, Single Phase (833 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM, 1.0 PF -24 Battery Volts -Powered by an 18.3L 10 Cylinder Twin Turbocharged Doosan Natural Gas / Propane Engine -Model Number: D183TIC -Serial Number: EES0D900874 -Part Number: 50000015 -Skid-Mounted -Radiator Cooled -Sound-Attenuated Enclosure -InteliGen NT Digital Control Panel -100 Amp & 800 Amp 3 Pole Square D Mainline Circuit Breakers -Jacket Water Heater -Alternator -Battery Charger -Electronic Governor -Muffler Assembly (Shipped Loose) -427 Total Hours Since New -Video Available -Generator Dimensions: 231"L x 90"W x 117"H -Muffler Assembly Dimensions: 92"L x 84"W -Weight (Wet): 14,695 lbs. -LOAD BANK TESTED -- SOLD |
|
|
350 kw Kohler / Doosan (Enclosed, 18.3L Doosan V10, 801 Hours, Mfg. 2011) Natural Gas/LP Genset
350 KW KOHLER / DOOSAN NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2011 -Generator End Model Number: 4M4019 -Generator Set Model Number: 350REZX -Generator Set Serial Number: 2327733 -Generator Set Spec: GM71300-GA5 -Standby Rated at 350 kw, 3 Phase (NG) or 240 kw, 3 Phase (LP) -Currently Setup 120/240 Volt, Single Phase (225 kw) -938 Amps -12 Lead Reconnectable -60 Hertz, 1800 RPM, 1.0 PF -24 Battery Volts -Powered by an 18.3L Doosan V10 Turbocharged Natural Gas / Propane Engine -Currently Setup for Vapor Propane Use -Engine Model Number: D183L -Engine Serial Number: EES0D901192 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure (w/ Interior Lighting) -Kohler Decision-Maker 3+ 16 Light Analog Control Panel -400-1000 Amp 3 Pole Adjustable Square D Mainline Circuit Breaker -Jacket Water Heater -Battery Charger -Electronic Governor -Mufflers (Mounted Inside Enclosure) -801 Total Hours Since New -Video Available -Dimensions: 249"L x 89"W x 112"H -LOAD BANK TESTED -- SOLD |
|
|
396 kw Baldor / Doosan (Sound-Attenuated, 21.9L V12 Doosan, 527 Hours, Mfg. 2010) Natural Gas/LP Genset
396 KW BALDOR / DOOSAN NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2010 -Model Number: IGLC420-2N -Serial Number: P1012210007 -Spec: 10.N2420-G8 -Standby Rated -396 kw, 3 Phase or 300 kw, Single Phase (NG) -259 kw, 3 Phase or 250 kw, Single Phase (LP) -Currently Setup 120/240 Volt, Single Phase (1042 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM, 1.0 PF -24 Battery Volts -Powered by a 21.9L V12 Twin Turbocharged Doosan Natural Gas / Propane Engine -Model Number: D219TIC -Serial Number: EEYOF901574 -Part Number: 50000016 -Skid-Mounted -Radiator Cooled -Sound-Attenuated Enclosure -Baldor InteliLite NT MRS19 Digital Control Panel -(1) 60/150 Amp Adjustable Merlin Gerin Circuit Breaker & (1) 1000 Amp Square D Circuit Breaker -Jacket Water Heater -Alternator -Battery Charger -Electronic Governor -Muffler Assembly (Shipped Loose) -527 Total Hours Since New -Video Available -Generator Dimensions: 248"L x 102"W x 119"H -Muffler Assembly Dimensions: 101"L x 96"W -Weight (Wet): 18,460 lbs. -LOAD BANK TESTED -- SOLD |
back to categories
 |
 |