20 kw MTU / Ford (Sound-Attenuated, 2.5L 4 Cyl. Ford, 92 Hours, Mfg. 2017) Natural Gas/LP Genset
20 KW MTU / FORD NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2017 -Marathon Generator End -Generator Set Model Number: GG04RF063V1M00007 -Generator Set Serial Number: 94070500054 -Standby Rated at 20 kw / 20 kva -Currently Setup 120/240 Volt, Single Phase (83 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 2.5L 4 Cylinder Ford Natural Gas / Propane Engine -Engine Model Number: XG3134200012 -Engine Serial Number: E1121240217132112 -Skid-Mounted -Radiator Cooled -Sound-Attenuated Enclosure -Basler DGC-2020ES Digital Control Panel -80 Amp 3 Pole Square D Mainline Circuit Breaker -Jacket Water Heater -Alternator -Battery Charger -Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed -92 Total Hours Since New -Dimensions: 92"L x 39"W x 63"H -LOAD BANK TESTED -- $12,900 |
|
|
20 kw Olympian / Ford (Enclosed, 2.5L 4 Cyl. Ford, 397 Hours, Mfg. 1999) Natural Gas/LP Genset
20 KW OLYMPIAN / FORD NATURAL GAS OR PROPANE GENERATOR
-Mfg. 1999 -Model Number: G25F1S -Serial Number: E5929A/101 -Standby Rated at 20 kw / 20 kva -Setup 120/240 Volt, Single Phase ONLY (104.2 Amps) -NOT Reconnectable to Other Voltages -4 Wire -60 Hertz, 1800 RPM, 1.0 PF -12 Battery Volts -Powered by a 2.5L Inline 4 Cylinder Ford Natural Gas / Propane Engine -Model Number: LRG425 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -FG Wilson 2001 Analog Control Panel -125 Amp 3 Pole ABB Mainline Circuit Breaker -Jacket Water Heater -Alternator -Woodward TQ125 Electronic Governor -Muffler (Mounted Inside Enclosure) -397 Total Hours Since New -Dimensions: 74"L x 37"W x 58"H -LOAD BANK TESTED -- $10,500 |
|
|
22 kw Generac (Sound-Attenuated, 2.4L 4 Cyl. Engine, 48 Hours, Mfg. 2020) Natural Gas/LP Genset
22 KW GENERAC NATURAL GAS / PROPANE GENERATOR
-Mfg. 2020 -Protector QS Series -Model Number: RG02224JNAX -Serial Number: 3005676513 -Standby Rated at 22 kw / 28 kva -Setup 120/240 Volt, 3 Phase Delta (66 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 2.4L 4 Cylinder Natural Gas / Propane Engine -Skid-Mounted -Radiator Cooled -Aluminum Sound-Attenuated Enclosure -Evolution Controller -80 Amp Mainline Circuit Breaker -Alternator -Electronic Governor -ETL Listed -48 Hours Since New -Dimensions: 63"L x 31"W x 39"H -- COMING IN! |
|
|
30 kw Katolight / GM (Open Frame, 4.3L GM V6, 209 Hours, Mfg. 2008) Natural Gas/LP Genset
30 KW KATOLIGHT / GM NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2008 -Marathon Generator End -Generator Set Model Number: NL30PG6 -Generator Set Serial Number: 302812-1-1-1008 -Standby Rated at 30 kw / 38 kva -Currently Setup 120/208 Volt, 3 Phase (104 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 4.3L GM V6 Vortec Natural Gas / Propane Engine -Engine Model Number: GM-4.3L -Engine Serial Number: 4P3L49178 -Skid-Mounted -Radiator Cooled -Open Frame -Kassec 1.5 Analog Control Panel -125 Amp 3 Pole GE Mainline Circuit Breaker -Jacket Water Heater -Alternator -Battery Charger -Electronic Governor -UL Listed & CSA Approved -209 Total Hours Since New -Dimensions: 76"L x 37"W x 46"H -LOAD BANK TESTED -- $11,900 |
|
|
30 kw Olympian / Ford (Enclosed, 4.2L Ford V6, 138 Hours, Mfg. 2001) Natural Gas/LP Genset
30 KW OLYMPIAN / FORD NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2001 -Model Number: G30F3 -Serial Number: OLY00000ENFS00294 -Standby Rated at 30 kw / 37.5 kva -Currently Setup 120/208 Volt, 3 Phase (104.1 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 4.2L Ford V6 Natural Gas / Propane Engine -Model Number: ESG642I6005E -Serial Number: 01-05-005323 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -FG Wilson 4001E Analog Control Panel -125 Amp 3 Pole ABB Mainline Circuit Breaker -Jacket Water Heater -Alternator -Woodward LCS Electronic Governor -Muffler (Mounted Inside Enclosure) -138 Total Hours Since New -Dimensions: 86"L x 37"W x 61"H -LOAD BANK TESTED -- $11,900 |
|
|
30 kw Katolight / GM (Open Frame, 4.3L GM V6, 262 Hours, Mfg. 2008) Natural Gas/LP Genset
30 KW KATOLIGHT / GM NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2008 -Model Number: NL30FGG4 38335 -Serial Number: 158765-0308 -Standby Rated at 30 kw / 30 kva -Currently Setup 120/240 Volt, Single Phase (125 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 4.3L GM V6 Natural Gas / Propane Engine -Model Number: GM-4.3L -Serial Number: 4P3L45825 -Skid-Mounted -Radiator Cooled -Open Frame -Kassec 1.5 Analog Control Panel -125 Amp 3 Pole GE Mainline Circuit Breaker -Jacket Water Heater -Alternator -Battery Charger -Electronic Governor -UL Listed & CSA Approved -262 Total Hours Since New -Dimensions: 77"L x 38"W x 77"H -LOAD BANK TESTED -- $11,900 |
|
|
35 kw Onan / Ford (Enclosed, 4.2L Ford V6, 460 Hours, Mfg. 2005) Natural Gas/LP Genset
35 KW ONAN / FORD NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2005 -Model Number: GGFD-5703254 -Serial Number: A050739641 -Spec: E -Standby Rated at 35 kw, 3 Phase or 23.5 kw, Single Phase -Currently Setup 120/208 Volt, 3 Phase (121.4 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 4.2L Ford V6 Natural Gas / Propane Engine -Model Number: ESG642 -Serial Number: 05ZK38788 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -PowerCommand 2100 Digital Control Panel -100 Amp 3 Pole Square D Mainline Circuit Breaker -Jacket Water Heater -Alternator -Battery Charger -Woodward L-Series Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed & CSA Approved -460 Total Hours Since New -Dimensions: 83"L x 41"W x 60"H -LOAD BANK TESTED -- $12,900 |
|
|
35 kw Generac / Ford (Sound-Attenuated, 5.4L Ford V8, 103 Hours, Mfg. 2016) Natural Gas/LP Genset
35 KW GENERAC / FORD NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2016 -Model Number: 1325200 -Serial Number: 3000069890 -Type Code: SG0035AG035.4V18HBLYA -Standby Rated at 35 kw / 35 kva -Setup 120/240 Volt, Single Phase ONLY (145 Amps) -NOT Reconnectable to Other Voltages -4 Wire -60 Hertz, 1800 RPM, 1.0 PF -12 Battery Volts -Powered by a 5.4L Ford V8 Natural Gas / Propane Engine -Skid-Mounted -Radiator Cooled -Sound-Attenuated Enclosure -Generac Digital Control Panel (H-Panel) -175 Amp 3 Pole Eaton Mainline Circuit Breaker -Jacket Water Heater -Alternator -Battery Charger -Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed -103 Total Hours Since New -Dimensions: 95"L x 38"W x 63"H -LOAD BANK TESTED -(8) IDENTICAL UNITS IN STOCK -- $13,500 ea. |
|
|
35 kw Katolight / GM (Enclosed, 4.3L GM V6, 130 Hours, Mfg. 2003) Natural Gas/LP Genset
35 KW KATOLIGHT / GM NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2003 -Model Number: N40FPG4 -Serial Number: LM383774-90497-0703 -Standby Rated at 35 kw, 3 Phase or 35 kw, Single Phase -Currently Setup 120/208 Volt, 3 Phase -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 4.3L GM V6 Vortec Natural Gas / Propane Engine -Model Number: GM-4.3L -Serial Number: 4.3L-16325 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -Basler DGC-2020 Digital Control Panel -150 Amp 3 Pole GE Mainline Circuit Breaker -Jacket Water Heater -Alternator -Battery Charger -Woodward LCS Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed & CSA Approved -130 Total Hours Since New -Dimensions: 70"L x 37"W x 54"H -LOAD BANK TESTED -- $12,900 |
|
|
35 kw Onan / Ford (Open Frame, 4.9L 6 Cyl. Ford, 862 Hours, Mfg. 2000) Natural Gas/LP Genset
35 KW ONAN / FORD NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2000 -Model Number: GGFB-3387978 -Serial Number: A000054144 -Spec: B -Standby Rated at 35 kw, 3 Phase or 23.5 kw, Single Phase -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 4.9L Inline 6 Cylinder Ford Natural Gas / Propane Engine -Model Number: CSG-649I-6005-A -Serial Number: 36688-1-04-98 -Skid-Mounted -Radiator Cooled -Open Frame -Detector Analog Control Panel -Mainline Circuit Breaker -Jacket Water Heater -Alternator -Woodward TQ-125 Electronic Governor -CSA Approved -862 Hours Since New -- COMING IN! |
|
|
40 kw Olympian / Ford (Sound-Attenuated, 5.4L Ford V8, 17 Hours, Mfg. 2016) Natural Gas/LP Genset
40 KW OLYMPIAN / FORD NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2016 -Model Number: G40LG2 -Serial Number: GXB04111-OLY00000 -Type Code: LG0040GG035.4N18HPSYA -Standby Rated at 40 kw / 50 kva -Upsize Alt: 50 kw -Currently Setup 120/208 Volt, 3 Phase (138 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 5.4L Ford V8 Natural Gas / Propane Engine -Serial Number: E172A 081215 3420474 -Skid-Mounted -Radiator Cooled -Sound-Attenuated Enclosure -Generac Digital Control Panel (H-Panel) -150 Amp 3 Pole Eaton Mainline Circuit Breaker -Jacket Water Heater -Alternator -Battery Charger -Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed -17 Total Hours Since New -Dimensions: 113"L x 38"W x 50"H -LOAD BANK TESTED -- $13,900 |
|
|
45 kw Kohler / Ford (Enclosed, 4.9L 6 Cyl. Ford, 639 Hours) Natural Gas/LP Genset
45 KW KOHLER / FORD NATURAL GAS OR PROPANE GENERATOR
-Model Number: 45RZ272 -Serial Number: 268093 -Spec: 183233-72L -Standby Rated at 45 kw, 3 Phase or 40 kw, Single Phase -Currently Setup 277/480 Volt, 3 Phase -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 4.9L Inline 6 Cylinder Ford Natural Gas / Propane Engine -Model Number: CSG-649I-6005-F -Serial Number: 06662 A-20-RH -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -Kohler Decision-Maker 3+ 16 Light Analog Control Panel -Jacket Water Heater -Alternator -GAC Electronic Governor -Muffler (Mounted Outside Enclosure) -639 Total Hours Since New -LOAD BANK TESTED -- $11,500 |
|
|
45 kw Kohler / GM (Enclosed, 4.3L GM V6, 868 Hours, Mfg. 2002) Natural Gas/LP Genset
45 KW KOHLER / GM NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2002 -Generator End Model Number: 4P7B -Generator Set Model Number: 45RZG -Generator Set Serial Number: 0732526 -Generator Set Spec: GM13685-GA6 -Standby Rated -45 kw, 3 Phase or 41 kw, Single Phase (LP) -40 kw, 3 Phase or 37 kw, Single Phase (NG) -Currently Setup 120/240 Volt, Single Phase (171 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 4.3L GM V6 Vortec Natural Gas / Propane Engine -Engine Model Number: GM-4.3L -Engine Serial Number: 4.3L-14758 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -Kohler Decision-Maker 3+ 16 Light Analog Control Panel -175 Amp 3 Pole Square D Mainline Circuit Breaker -Jacket Water Heater -Alternator -Barber Colman Electronic Governor -Muffler (Mounted Outside Enclosure) -868 Total Hours Since New -Dimensions: 88"L x 41"W x 69"H -LOAD BANK TESTED -- PLEASE CALL FOR PRICING! |
|
|
50 kw Kohler / GM (Enclosed, 5.0L GM V8, 118 Hours, Mfg. 2012) Natural Gas/LP Genset
50 KW KOHLER / GM NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2012 -Generator End Model Number: 4P7BX -Generator Set Model Number: 50REZGB -Generator Set Serial Number: SGM323MS9 -Generator Set Spec: GM79036-GA1 -Standby Rated at 50 kw / 63 kva -Currently Setup 120/208 Volt, 3 Phase (173 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 5.0L GM V8 Natural Gas / Propane Engine -Engine Model Number: GM-5.0L -Engine Serial Number: 5.0L 15142 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -Kohler APM402 Digital Control Panel -200 Amp 3 Pole Square D Mainline Circuit Breaker -Jacket Water Heater -Alternator -Battery Charger -Bosch Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed -118 Total Hours Since New -Dimensions: 102"L x 43"W x 60"H -LOAD BANK TESTED -- SOLD |
|
|
50 kw Generac / Ford (Sound-Attenuated, 6.8L Ford V10, 133 Hours, Mfg. 2015) Natural Gas/LP Genset
50 KW GENERAC / FORD NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2015 -Model Number: 0065781 -Serial Number: 9971586 -Standby Rated at 50 kw / 50 kva -Setup 120/240 Volt, Single Phase ONLY (208.3 Amps) -NOT Reconnectable to Other Voltages -4 Wire -60 Hertz, 1800 RPM, 1.0 PF -12 Battery Volts -Powered by a 6.8L Ford V10 Natural Gas / Propane Engine -Serial Number: E172A 220515 1420165 -Skid-Mounted -Radiator Cooled -Sound-Attenuated Enclosure -Generac Digital Control Panel (H-Panel) -200 Amp 3 Pole Eaton Mainline Circuit Breaker -Jacket Water Heater -Alternator -Battery Charger -Bosch Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed -133 Total Hours Since New -Dimensions: 112"L x 41"W x 72"H -LOAD BANK TESTED -- SALE PENDING! |
|
|
55 kw Kohler / GM (Enclosed, 5.0L GM V8, 161 Hours, Mfg. 2002) Natural Gas/LP Genset
55 KW KOHLER / GM NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2002 -Generator End Model Number: 4P8 -Generator Set Model Number: 50RZGB -Generator Set Serial Number: 0734243 -Generator Set Spec: GM21302-GA1 -Standby Rated -55 kw, 3 Phase or 49 kw, Single Phase (LP) -50 kw, 3 Phase or 48 kw, Single Phase (NG) -Currently Setup 120/208 Volt, 3 Phase (173 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 5.0L GM V8 Natural Gas / Propane Engine -Engine Model Number: GM-5.0L -Engine Serial Number: 5.0L-005100 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -Kohler Decision-Maker 3+ 16 Light Analog Control Panel -250 Amp 3 Pole Square D Mainline Circuit Breaker -Jacket Water Heater -Alternator -Battery Charger -Woodward LCS Electronic Governor -Muffler (Mounted Outside Enclosure) -CSA Approved -161 Total Hours Since New -Dimensions: 88"L x 42"W x 70"H -LOAD BANK TESTED -- SOLD |
|
|
55 kw Katolight / Hercules (Enclosed, 6 Cyl. Hercules, 415 Hours) Natural Gas/LP Genset
55 KW KATOLIGHT / HERCULES NATURAL GAS OR PROPANE GENERATOR
-Model Number: L55FGH4 -Serial Number: AD161521SRF C-40245 -Standby Rated at 55 kw / 55 kva -Currently Setup 120/240 Volt, Single Phase (229 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by an Inline 6 Cylinder Hercules Natural Gas / Propane Engine -Model Number: G3400 -Serial Number: JS3336141 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -Kassec 1.5 Analog Control Panel -200 Amp 3 Pole GE Mainline Circuit Breaker -Jacket Water Heater -Alternator -Mechanical Governor -Muffler (Mounted Inside Enclosure) -415 Total Hours Since New -Dimensions: 90"L x 40"W x 75"H -LOAD BANK TESTED -- $10,900 |
|
|
60 kw Onan / Ford (Partially Sound-Attenuated, 6.8L Ford V10, 447 Hours, Mfg. 2006) Natural Gas/LP Genset
60 KW ONAN / FORD NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2006 -Model Number: GGHE-5782042 -Serial Number: L060000107 -Spec: G -Standby Rated at 60 kw, 3 Phase or 60 kw, Single Phase -Currently Setup 120/240 Volt, Single Phase (250 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 6.8L Ford V10 Natural Gas / Propane Engine -Model Number: WSG1068 -Serial Number: 06QS60848 -Skid-Mounted -Radiator Cooled -Partially Sound-Attenuated Enclosure -PowerCommand 2100 Digital Control Panel -250 Amp 2 Pole Square D Mainline Circuit Breaker -Jacket Water Heater -Alternator -Battery Charger -Woodward L-Series Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed & CSA Approved -447 Total Hours Since New -Dimensions: 102"L x 41"W x 78"H -LOAD BANK TESTED -- SOLD |
|
|
60 kw Kohler / GM (Sound-Attenuated, 5.7L GM V8, 62 Hours, Mfg. 2011) Natural Gas/LP Genset
60 KW KOHLER / GM NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2011 -Generator End Model Number: 4S7 -Generator Set Model Number: 60REZG -Generator Set Serial Number: 3014428 -Generator Set Spec: GM66911-GA1 -Standby Rated -Currently Setup 277/480 Volt, 3 Phase (90 Amps) -Currently Setup for Propane Use -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 5.7L GM V8 Natural Gas / Propane Engine -Engine Model Number: GM-5.7L -Engine Serial Number: 5.7L20960 -Skid-Mounted -Radiator Cooled -Sound-Attenuated Enclosure -Kohler Decision-Maker 3000 Digital Control Panel -100 Amp 3 Pole Square D Mainline Circuit Breaker -Jacket Water Heater -Alternator -Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed -62 Total Hours Since New -Dimensions: 102"L x 43"W x 62"H -LOAD BANK TESTED -- SALE PENDING! |
|
|
60 kw Kohler / Ford (Enclosed, 7.5L Ford 460 V8, 1,071 Hours) Natural Gas/LP Genset
60 KW KOHLER / FORD NATURAL GAS OR PROPANE GENERATOR
-Model Number: 60RZ272 -Serial Number: 359604 -Spec: PA-187079-72N -Standby Rated at 60 kw / 75 kva -Setup 277/480 Volt, 3 Phase (90 Amps) -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 7.5L Ford 460 V8 Natural Gas / Propane Engine -Engine Model Number: LSG-875I-6005-A -Engine Serial Number: 15591 T-30-RA -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -Kohler Decision-Maker 3+ 16 Light Analog Control Panel -100 Amp 3 Pole Mainline Circuit Breaker -Jacket Water Heater -Alternator -Battery Charger -Electronic Governor -Muffler (Mounted Outside Enclosure) -1,071 Total Hours Since New -Dimensions: 92"L x 35"W x 63"H -- PLEASE CALL FOR PRICING! |
|
|
65 kw Onan / Ford (Enclosed, 7.5L Ford 460 V8, 922 Hours, Mfg. 2000) Natural Gas/LP Genset
65 KW ONAN / FORD NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2000 -Model Number: GGHB-4477798 -Serial Number: C000080666 -Spec: B -Standby Rated at 65 kw, 3 Phase or 43.6 kw, Single Phase -Currently Setup 277/480 Volt, 3 Phase (97.8 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 7.5L Ford 460 V8 Natural Gas / Propane Engine -Model Number: LSG-875I-6005-A -Serial Number: 16333-1-04-98 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -Detector Analog Control Panel -125 Amp 3 Pole Merlin Gerin Mainline Circuit Breaker -Jacket Water Heater -Alternator -Woodward TQ-125 Electronic Governor -Muffler (Mounted Inside Enclosure) -CSA Approved -922 Total Hours Since New -Dimensions: 83"L x 41"W x 60"H -LOAD BANK TESTED -- $15,900 |
|
|
65 kw Onan / Ford (Sound-Attenuated, 7.5L Ford 460 V8, 1,596 Hours, Mfg. 1998) Natural Gas/LP Genset
65 KW ONAN / FORD NATURAL GAS OR PROPANE GENERATOR
-Mfg. 1998 -Model Number: 65GGHB -Serial Number: A980673066 -Spec: 92795A -Standby Rated at 65 kw, 3 Phase or 43.6 kw, Single Phase -Currently Setup 120/240 Volt, Single Phase (182 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 7.5L Ford 460 V8 Natural Gas / Propane Engine -Model Number: LSG-875I-6005-A -Serial Number: 24045 E-14-RH -Skid-Mounted -Radiator Cooled -Sound-Attenuated Enclosure -Belimo Powered Louvers -Detector Analog Control Panel -CJ400N 3 Pole Merlin Gerin Compact Mainline Circuit Breaker (w/ 300 Amp Plug) -Jacket Water Heater -Alternator -Woodward TQ125 Electronic Governor -1,596 Total Hours Since New -Dimensions: 127"L x 56"W x 74"H -LOAD BANK TESTED -- $15,900 |
|
|
70 kw Generac / Ford (Sound-Attenuated, 6.8L Ford V10, 93 Hours, Mfg. 2007) Natural Gas/LP Genset
70 KW GENERAC / FORD NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2007 -Model Number: 8069290100 -Serial Number: 2093317 -Type Code: SG0070-K366.8N18HBSYC -Standby Rated at 70 kw / 88 kva -Currently Setup 277/480 Volt, 3 Phase (105.2 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 6.8L Ford V10 Natural Gas / Propane Engine -Model Number: WSG1068 -Serial Number: 07XS64331 -Skid-Mounted -Radiator Cooled -Sound-Attenuated Enclosure -Generac Digital Control Panel (H-Panel) -(2) 60 Amp 3 Pole Siemens Mainline Circuit Breakers -Jacket Water Heater -Alternator -Battery Charger -Bosch Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed -93 Total Hours Since New -Dimensions: 112"L x 41"W x 69"H -LOAD BANK TESTED -- SALE PENDING! |
|
|
75 kw Onan / Ford (Sound-Attenuated, 6.8L Ford V10, 305 Hours, Mfg. 2007) Natural Gas/LP Genset
75 KW ONAN / FORD NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2007 -Model Number: GGHF-5856273 -Serial Number: D070047391 -Spec: G -Standby Rated at 75 kw, 3 Phase or 50.3 kw, Single Phase -Currently Setup 120/240 Volt, 3 Phase (225.5 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 6.8L Ford V10 Natural Gas / Propane Engine -Model Number: WSG1068 -Serial Number: 07XS64544 -Skid-Mounted -Radiator Cooled -Sound-Attenuated Enclosure -PowerCommand 2100 Digital Control Panel -225 Amp 3 Pole Square D Mainline Circuit Breaker -Jacket Water Heater -Alternator -Woodward L-Series Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed & CSA Approved -305 Total Hours Since New -Dimensions: 102"L x 41"W x 77"H -LOAD BANK TESTED -- SOLD |
|
|
77 kw Kohler / GM (Open Frame, 5.7L GM V8, 50 Hours, Mfg. 2015) Natural Gas/LP Genset
77 KW KOHLER / GM NATURAL GAS GENERATOR
-Mfg. 2015 -Generator End Model Number: 4P10X -Generator Set Model Number: 80REZGD -Generator Set Serial Number: SGM32DVK3 -Generator Set Spec: GM81112-GA1 -Standby Rated -Setup for Natural Gas Use Only -Rated 80 kw @ 277/480 Volt, 3 Phase -Rated 77 kw @ 120/208 Volt, 3 Phase -Rated 63 kw @ 120/240 Volt, Single Phase -Currently Setup 120/208 Volt, 3 Phase (267 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 5.7L GM V8 Turbocharged Natural Gas Engine -Engine Model Number: GM-5.7L -Engine Serial Number: 5.7L35398 -Skid-Mounted -Radiator Cooled -Open Frame -Kohler Decision-Maker 3000 Digital Control Panel -400 Amp 3 Pole Square D Mainline Circuit Breaker -Jacket Water Heater -Alternator -Battery Charger -Bosch Electronic Governor -UL Listed -50 Total Hours Since New -Dimensions: 111"L x 44"W x 55"H -LOAD BANK TESTED -- $16,500 |
|
|
80 kw Kohler / Ford (Enclosed, 7.5L Ford 460 V8, 633 Hours) Natural Gas/LP Genset
80 KW KOHLER / FORD NATURAL GAS OR PROPANE GENERATOR
-Serial Number: 393776 -Standby Rated at 80 kw / 100 kva -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 7.5L Ford 460 V8 Turbocharged Natural Gas / Propane Engine -Engine Model Number: LSG-875I-6005-A -Engine Serial Number: 20130 R-22-RH -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -Kohler Decision-Maker 3+ 16 Light Analog Control Panel -Jacket Water Heater -Alternator -Electronic Governor -Muffler (Mounted Outside Enclosure) -633 Total Hours Since New -- PLEASE CALL FOR PRICING! |
|
|
80 kw Kohler / Ford (Enclosed, 7.5L Ford 460 V8, 804 Hours) Natural Gas/LP Genset
80 KW KOHLER / FORD NATURAL GAS OR PROPANE GENERATOR
-Model Number: 80RZ82 -Serial Number: 355408 -Spec: PA-187341-82N -Standby Rated -80 kw @ All 3 Phase Voltages (NG or LP) -76 kw, Single Phase (NG or LP) -Currently Setup 120/208 Volt, 3 Phase (278 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 7.5L Ford 460 V8 Natural Gas / Propane Engine -Engine Model Number: LSG-875I-6005-A -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -Kohler Decision-Maker 3+ 16 Light Analog Control Panel -225 Amp 3 Pole Square D Mainline Circuit Breaker -Safeguard Breaker -Jacket Water Heater -Alternator -Barber Colman Electronic Governor -Muffler (Mounted Outside Enclosure) -805 Total Hours Since New -Dimensions: 89"L x 35"W x 69"H -LOAD BANK TESTED -- PLEASE CALL FOR PRICING! |
|
|
80 kw Kohler / Ford (Open Frame, 7.5L Ford 460 V8, 503 Hours) Natural Gas/LP Genset
80 KW KOHLER / FORD NATURAL GAS OR PROPANE GENERATOR
-Model Number: 80RZ72 -Serial Number: 350693 -Spec: PA-187341-72N -Standby Rated at 80 kw / 100 kva -Setup 277/480 Volt, 3 Phase (120 Amps) -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 7.5L Ford 460 V8 Turbocharged Natural Gas / Propane Engine -Model Number: LSG-875I-6005-A -Serial Number: 14026 T-30-RL -Skid-Mounted -Radiator Cooled -Open Frame -Kohler Decision-Maker 3+ 16 Light Analog Control Panel -Jacket Water Heater -Alternator -Electronic Governor -Muffler (Shipped Loose) -503 Total Hours Since New -Dimensions: 91"L x 35"W x 52"H -- PLEASE CALL FOR PRICING! |
|
|
85 kw Onan / Ford (Enclosed, 6.8L Ford V10, 97 Hours, Mfg. 2003) Natural Gas/LP Genset
85 KW ONAN / FORD NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2003 -Model Number: GGHG-5632810 -Serial Number: I030550878 -Spec: D -Standby Rated at 85 kw, 3 Phase or 57 kw, Single Phase -Currently Setup 277/480 Volt, 3 Phase (127.8 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 6.8L Ford V10 Turbocharged Natural Gas / Propane Engine -Model Number: WSG-1068I-6005-A -Serial Number: 03-09-060738 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -Detector Analog Control Panel -125 Amp 3 Pole Merlin Gerin Mainline Circuit Breaker -Jacket Water Heater -Alternator -Woodward Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed & CSA Approved -97 Total Hours Since New -Dimensions: 105"L x 41"W x 64"H -LOAD BANK TESTED -- SOLD |
|
|
95 kw Kohler / GM (Sound-Attenuated, 8.1L GM V8, 203 Hours, Mfg. 2004) Natural Gas/LP Genset
95 KW KOHLER / GM NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2004 -Generator End Model Number: 4V11 -Generator Set Model Number: 100RZG -Generator Set Serial Number: 2015868 -Generator Set Spec: GM34436-GA6 -Standby Rated at 95 kw / 95 kva -Setup 120/240 Volt, Single Phase ONLY (396 Amps) -NOT Reconnectable to Other Voltages -4 Wire -60 Hertz, 1800 RPM, 1.0 PF -12 Battery Volts -Powered by an 8.1L GM V8 Natural Gas / Propane Engine -Skid-Mounted -Radiator Cooled -Sound-Attenuated Enclosure -Control Panel -400 Amp Mainline Circuit Breaker -Jacket Water Heater -Alternator -Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed -203 Hours Since New -- COMING IN! |
|
|
100 kw Generac (Enclosed, 9.0L V8 Engine, 242 Hours, Mfg. 2012) Natural Gas/LP Genset
100 KW GENERAC NATURAL GAS / PROPANE GENERATOR
-Mfg. 2012 -Model Number: 14549480200 -Serial Number: 2117219 -Type Code: SG0100KG189.0N18HPYYE -Standby Rated at 100 kw / 125 kva -Currently Setup 277/480 Volt, 3 Phase (150.3 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 9.0L V8 Natural Gas / Propane Engine -Serial Number: 0K0223 -Rated 149 HP @ 1800 RPM -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -Generac Digital Control Panel (H-Panel) -175 Amp 3 Pole Generac Mainline Circuit Breaker -Jacket Water Heater -Alternator -Electronic Governor -Muffler (Mounted Inside Enclosure) -242 Total Hours Since New -Dimensions: 112"L x 41"W x 56"H -LOAD BANK TESTED -- SOLD |
|
|
100 kw Kohler / Ford (Enclosed, 7.5L Ford 460 V8, 805 Hours, Mfg. 2000) Natural Gas/LP Genset
100 KW KOHLER / FORD NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2000 -Generator End Model Number: 4S9 -Generator Set Model Number: 100RZ -Generator Set Serial Number: 0683674 -Generator Set Spec: PA-187444 -Standby Rated -100 kw, 3 Phase (NG) or 90 kw, 3 Phase (LP) -Setup 277/480 Volt, 3 Phase (150 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 7.5L Ford 460 V8 Turbocharged Natural Gas / Propane Engine -Engine Model Number: LSG-875I-6005-A -Engine Serial Number: 22042-1-04-98 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -Kohler Decision-Maker 3+ 16 Light Analog Control Panel -Jacket Water Heater -Alternator -Barber Colman Electronic Governor -Muffler (Mounted Outside Enclosure) -CSA Approved -805 Total Hours Since New -Dimensions: 91"L x 35"W x 70"H -(2) IN STOCK -- PLEASE CALL FOR PRICING! |
|
|
100 kw Onan / Ford (Enclosed, 6.8L Ford V10, 1,243 Hours, Mfg. 2013) Natural Gas/LP Genset
100 KW ONAN / FORD NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2013 -Model Number: GGHH-1334977 -Serial Number: H130550035 -Spec: L -Standby Rated at 100 kw, 3 Phase or 67 kw, Single Phase -Currently Setup 277/480 Volt, 3 Phase (150.4 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 6.8L Ford V10 Turbocharged Natural Gas / Propane Engine -Model Number: WSG1068 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -PowerCommand 2100 Digital Control Panel -225 Amp 3 Pole Square D Mainline Circuit Breaker -Jacket Water Heater -Alternator -Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed & CSA Approved -1,243 Total Hours Since New -Dimensions: 107"L x 41"W x 70"H -LOAD BANK TESTED -- SOLD |
|
|
100 kw Kohler / Ford (Open Frame, 7.5L Ford 460 V8, 1,271 Hours) Natural Gas/LP Genset
100 KW KOHLER / FORD NATURAL GAS OR PROPANE GENERATOR
-Model Number: 100RZ272 -Serial Number: 273673 -Spec: 187435-72N -Standby Rated at 100 kw, 3 Phase or 80 kw, Single Phase -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by a 7.5L Ford 460 V8 Turbocharged Natural Gas / Propane Engine -Model Number: LSG-875I-6005-A -Serial Number: 13927 T-17-RM -Skid-Mounted -Radiator Cooled -Open Frame -Kohler Decision-Maker 3+ 16 Light Analog Control Panel -Westinghouse Mainline Circuit Breaker -Jacket Water Heater -Alternator -Barber Colman Electronic Governor -1,271 Total Hours Since New -Dimensions: 91"L x 35"W x 50"H -- PLEASE CALL FOR PRICING! |
|
|
100 kw Onan / Ford (Enclosed, 6.8L Ford V10, 264 Hours, Mfg. 2001) Natural Gas/LP Genset
100 KW ONAN / FORD NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2001 -Model Number: GGHH-4963844 -Serial Number: H010270369 -Spec: A -Standby Rated at 100 kw / 100 kva -Setup 120/240 Volt, Single Phase ONLY (416.7 Amps) -NOT Reconnectable to Other Voltages -4 Wire -60 Hertz, 1800 RPM, 1.0 PF -12 Battery Volts -Powered by a 6.8L Ford V10 Turbocharged Natural Gas / Propane Engine -Model Number: WSG1068IT-6005-A -Serial Number: 01-06-006513 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -Detector Analog Control Panel -200 Amp 2 Pole ITE Mainline Circuit Breaker -Jacket Water Heater -Alternator -Woodward LCS Electronic Governor -Muffler (Mounted Inside Enclosure) -CSA Approved -264 Total Hours Since New -Dimensions: 105"L x 41"W x 62"H -LOAD BANK TESTED -- SOLD |
|
|
125 kw Cummins / Onan (Enclosed, 8.3L 6 Cyl. Cummins, 2,173 Hours, Mfg. 1999) Natural Gas/LP Genset
125 KW CUMMINS / ONAN NATURAL GAS OR PROPANE GENERATOR
-Mfg. 1999 -Model Number: GGKB-3377626 -Serial Number: J990986933 -Spec: A -Standby Rated 125 kw, 3 Phase or 125 kw, Single Phase -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by an 8.3L Inline 6 Cylinder Turbocharged Cummins Natural Gas / Propane Engine -Model Number: GTA8.3G1 -Rated 202 HP @ 1800 RPM -Compression Ratio: 8.5:1 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -PowerCommand Digital Control Panel -Mainline Circuit Breaker -Altronic Ignition System -Muffler (Mounted Outside Enclosure) -2,173 Hours Since New -- COMING IN! |
|
|
125 kw Olympian / GM (Sound-Attenuated, 8.1L GM V8, 4,360 Hours, Mfg. 2007) Natural Gas/LP Genset
125 KW OLYMPIAN / GM NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2007 -Model Number: G125G1 -Serial Number: OLY00000VNGG00623 -Standby Rated at 125 kw / 156.3 kva -Currently Setup 120/208 Volt, 3 Phase (434 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by an 8.1L GM V8 Turbocharged Natural Gas / Propane Engine -Model Number: GM-8.1L -Serial Number: 8P1L15708 -Skid-Mounted -Radiator Cooled -Sound-Attenuated Enclosure -Caterpillar EMCP 4.2 Digital Control Panel -240-600 Amp 3 Pole Adjustable ABB Mainline Circuit Breaker (Set at 480 Amps) -Jacket Water Heater -Alternator -Battery Charger -Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed & CSA Approved -4,360 Total Hours Since New -Video Available -Dimensions: 123"L x 53"W x 68"H -LOAD BANK TESTED -- $19,500 |
|
|
125 kw Cummins / Onan (Enclosed, 8.3L 6 Cyl. Cummins, 292 Hours, Mfg. 2000) Natural Gas/LP Genset
125 KW CUMMINS / ONAN NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2000 -Model Number: GGKB-4479132 -Serial Number: D000085823 -Spec: A -Standby Rated 125 kw, 3 Phase or 125 kw, Single Phase -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by an 8.3L Inline 6 Cylinder Turbocharged Cummins Natural Gas / Propane Engine -Model Number: GTA8.3G1 -Engine Number: 45954014 -Rated 202 HP @ 1800 RPM -Compression Ratio: 8.5:1 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -PowerCommand Digital Control Panel -Mainline Circuit Breaker -Electronic Governor -Altronic Ignition System -Muffler (Mounted Outside Enclosure) -CSA Approved -292 Hours Since New -- COMING IN! |
|
|
125 kw Kohler / GM (Drop-Over Enclosure, 8.1L GM V8, 279 Hours, Mfg. 2004) Natural Gas/LP Genset
125 KW KOHLER / GM NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2004 -Generator End Model Number: 4S11 -Generator Set Model Number: 125RZG -Generator Set Serial Number: 2021880 -Generator Set Spec: GM34464-GA1 -Standby Rated -125 kw, 3 Phase or 95 kw, Single Phase (NG) -105 kw, 3 Phase or 95 kw, Single Phase (LP) -Currently Setup 277/480 Volt, 3 Phase (188 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by an 8.1L GM V8 Turbocharged Natural Gas / Propane Engine -Engine Model Number: GM-8.1L -Engine Serial Number: 8P1L09674S04 -Skid-Mounted -Radiator Cooled -Weatherproof Drop-Over Enclosure -Kohler Decision-Maker 3+ 16 Light Analog Control Panel -150 Amp & 200 Amp 3 Pole Square D Circuit Breakers -Jacket Water Heater -Alternator -PSI / Bosch Electronic Governor -Muffler (Mounted Outside Enclosure) -UL Listed -279 Total Hours Since New -Generator Dimensions: 95"L x 35"W x 55"H -Enclosure Dimensions: 111"L x 51"W x 81"H -LOAD BANK TESTED -- SOLD |
|
|
130 kw Kohler / GM (Partially Sound-Attenuated, 8.1L GM V8, 320 Hours, Mfg. 2003) Natural Gas/LP Genset
130 KW KOHLER / GM NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2003 -Generator End Model Number: 4S13 -Generator Set Model Number: 125RZG -Generator Set Serial Number: 0767723 -Generator Set Spec: ES-64449-GA1 -Standby Rated -130 kw, 3 Phase or 100 kw, Single Phase (NG) -110 kw, 3 Phase or 100 kw, Single Phase (LP) -Currently Setup 277/480 Volt, 3 Phase (195 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by an 8.1L GM V8 Turbocharged Natural Gas / Propane Engine -Engine Model Number: GM-8.1L -Engine Serial Number: 8.1L 07589 -Skid-Mounted -Radiator Cooled -Partially Sound-Attenuated Enclosure -Kohler Decision-Maker 3+ 16 Light Analog Control Panel -40 Amp & 125 Amp 3 Pole Square D Circuit Breakers -Jacket Water Heater -Alternator -Battery Charger -Electronic Governor -(4) Vibration Feet (Mounted) -Muffler (Mounted Outside Enclosure) -UL Listed -320 Total Hours Since New -Video Available -Dimensions: 95"L x 46"W x 87"H -LOAD BANK TESTED -- SOLD |
|
|
130 kw Kohler / GM (Open Frame, 728 Hours, Mfg. 2003) Natural Gas/LP Genset
130 KW KOHLER / GM NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2003 -Generator End Model Number: 4S13 -Generator Set Model Number: 125RZG -Generator Set Serial Number: 0757789 -Generator Set Spec: GM25339-GA1 -Standby Rated -130 kw, 3 Phase or 100 kw, Single Phase (NG) -110 kw, 3 Phase or 100 kw, Single Phase (LP) -Currently Setup 277/480 Volt, 3 Phase (195 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by an 8.1L GM V8 Turbocharged Natural Gas / Propane Engine -Engine Model Number: GM-8.1L -Engine Serial Number: 8.1L-07214 -Skid-Mounted -Radiator Cooled -Open Frame -Kohler Decision-Maker 3+ 16 Light Analog Control Panel -(2) Circuit Breakers -Jacket Water Heater -728 Hours Since New -- COMING IN! |
|
|
130 kw Katolight / GM (Enclosed, 8.1L GM V8, 157 Hours, Mfg. 2008) Natural Gas/LP Genset
130 KW KATOLIGHT / GM NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2008 -Model Number: SNL130RG6 -Serial Number: 301641-1-1-1108 -Standby Rated at 130 kw / 163 kva -Currently Setup 277/480 Volt, 3 Phase (195 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by an 8.1L GM V8 Turbocharged Natural Gas / Propane Engine -Model Number: GM-8.1L -Serial Number: 8P1L19457 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -Basler DGC-2020 Digital Control Panel -225 Amp 3 Pole GE Mainline Circuit Breaker -Jacket Water Heater -Alternator -Battery Charger -Bosch Electronic Governor (PSI Engine) -Muffler (Mounted Inside Enclosure) -UL Listed & CSA Approved -157 Total Hours Since New -Video Available -Dimensions: 93"L x 58"W x 74"H -LOAD BANK TESTED -- SOLD |
|
|
150 kw Kohler / GM (Sound-Attenuated, 8.1L GM V8, 304 Hours, Mfg. 2010) Natural Gas/LP Genset
150 KW KOHLER / GM NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2010 -Generator End Model Number: 4S13 -Generator Set Model Number: 150REZG -Generator Set Serial Number: 2300146 -Generator Set Spec: GM64060-GA1 -Standby Rated -150 kw, 3 Phase (NG) -125 kw, 3 Phase (LP) -Currently Setup 277/480 Volt, 3 Phase (226 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by an 8.1L GM V8 Natural Gas / Propane Engine -Engine Model Number: GM-8.1L -Engine Serial Number: 8P1L22728 -Skid-Mounted -Radiator Cooled -Sound-Attenuated Enclosure -Kohler Decision-Maker 550 Digital Control Panel -600 Amp 3 Pole Adjustable Square D Mainline Circuit Breaker (Set at 300 Amps) -Jacket Water Heater -Alternator -Battery Charger -Bosch Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed -304 Total Hours Since New -Dimensions: 138"L x 49"W x 66"H -LOAD BANK TESTED -- SOLD |
|
|
150 kw Onan / GM (Open Frame, 8.1L GM V8, 30 Hours, Mfg. 2005) Natural Gas/LP Genset
150 KW ONAN / GM NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2005 -Model Number: GGLB-5703479 -Serial Number: A050742761 -Spec: A -Standby Rated at 150 kw, 3 Phase or 100.5 kw, Single Phase -Currently Setup 277/480 Volt, 3 Phase (225.5 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by an 8.1L GM V8 Turbocharged Natural Gas / Propane Engine -Model Number: GM-8.1L -Serial Number: 8P1L10172 -Skid-Mounted -Radiator Cooled -Open Frame -PowerCommand 2100 Digital Control Panel -250 Amp 3 Pole Merlin Gerin Mainline Circuit Breaker -Jacket Water Heater -Alternator -Electronic Governor -Pallet Including Muffler, Flex Pipe, Battery Charger, Vibration Feet, & Gas Line -CSA Approved -30 Total Hours Since New -Video Available -Generator Dimensions: 93"L x 41"W x 56"H -Pallet Dimensions: 78"L x 43"W x 35"H -LOAD BANK TESTED -- $29,500 |
|
|
150 kw Kohler / 50 Series Detroit (Open Frame, 8.5L 4 Cyl. Detroit, 1,092 Hours, Mfg. 2003) Natural Gas/LP Genset
150 KW KOHLER / 50 SERIES DETROIT NATURAL GAS GENERATOR
-Mfg. 2003 -Generator End Model Number: 4S13 -Generator Set Model Number: 150RZD -Generator Set Serial Number: 0758967 -Standby Rated at 150 kw / 188 kva -Currently Setup 120/208 Volt, 3 Phase (520 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -24 Battery Volts -Powered by an 8.5L 4 Cylinder Turbocharged 50 Series Detroit Natural Gas Engine -Unit Number: 04R0042249 -S.O. Number: 851891 -Model Number: 6043TKG5 -Spec: A 343044 -Rated 260 HP @ 1800 RPM -Skid-Mounted -Radiator Cooled -Open Frame -Kohler Decision-Maker 3+ 16 Light Analog Control Panel -600 Amp 3 Pole Square D Mainline Circuit Breaker -Jacket Water Heater -Alternator -Battery Charger -Electronic Governor -Exhaust Flex Pipe (Mounted) -1,092 Total Hours Since New -Video Available -Dimensions: 115"L x 51"W x 80"H -- $32,500 |
|
|
150 kw Onan / GM (Sound-Attenuated, 8.1L GM V8, 518 Hours, Mfg. 2011) Natural Gas/LP Genset
150 KW ONAN / GM NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2011 -Model Number: GGLB-9314803 -Serial Number: L110287338 -Spec: J -Standby Rated at 150 kw (Natural Gas) or 140 kw (Propane) -Currently Setup 277/480 Volt, 3 Phase -12 Lead Reconnectable -60 Hertz, 1800 RPM -12 Battery Volts -Powered by an 8.1L GM V8 Turbocharged Natural Gas / Propane Engine -Model Number: GM-8.1L -Serial Number: 8P1L12284 -Skid-Mounted -Radiator Cooled -Sound-Attenuated Enclosure -PowerCommand 2100 Digital Control Panel -160/400 Amp 3 Pole Adjustable Merlin Gerin Mainline Circuit Breaker (Set at 304 Amps) -Jacket Water Heater -Alternator -Battery Charger -Electronic Governor -Muffler (Mounted Inside Enclosure) -UL Listed & CSA Approved -518 Total Hours Since New -Dimensions: 143"L x 41"W x 71"H -LOAD BANK TESTED -- SOLD |
|
|
150 kw MTU / Detroit (Enclosed, 50 Series Detroit, 1,665 Hours, Mfg. 2004) Natural Gas/LP Genset
150 KW MTU / DETROIT NATURAL GAS GENERATOR
-Mfg. 2004 -Generator End Model Number: 4S13 -Generator Set Model Number: 150GS -Generator Set Serial Number: 2022756 -Generator Set Spec: GM16894-GA1S -Standby Rated at 150 kw / 188 kva -Currently Setup 277/480 Volt, 3 Phase (226 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -24 Battery Volts -Powered by an 8.5L 4 Cylinder Turbocharged 50 Series Detroit Natural Gas Engine -Engine Serial Number: 04R0046605 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -Kohler Decision-Maker 550 Digital Control Panel -200 Amp 3 Pole Square D Mainline Circuit Breaker -Jacket Water Heater -Alternator -Battery Charger -Electronic Governor -Muffler (Mounted Outside Enclosure) -1,665 Total Hours Since New -Dimensions: 117"L x 51"W x 104"H -LOAD BANK TESTED -- $34,500 |
|
|
180 kw Kohler / Detroit (Enclosed, 8.5L 4 Cyl. Detroit, 1,354 Hours, Mfg. 1997) Natural Gas/LP Genset
180 KW KOHLER / 50 SERIES DETROIT NATURAL GAS GENERATOR
-Mfg. 1997 -Model Number: 180RZD -Serial Number: 601607 -Spec: PA-194044 -Standby Rated at 180 kw / 225 kva -Currently Setup 277/480 Volt, 3 Phase (271 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -24 Battery Volts -Powered by an 8.5L 4 Cylinder Turbocharged 50 Series Detroit Natural Gas Engine -Setup for Natural Gas ONLY -Unit Number: 04R0023990 -S.O. Number: 432706 -Model Number: 6043GKG5 -Spec: A 343019 -Tested at 300 HP @ 1800 RPM -Compression Ratio: 10.0:1 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -Kohler Decision-Maker 3+ 16 Light Analog Control Panel -300 Amp 3 Pole Square D Mainline Circuit Breaker -Jacket Water Heater -Alternator -Electronic Governor -Muffler (Mounted Outside Enclosure) -1,354 Total Hours Since New -Dimensions: 117"L x 52"W x 95"H -- SOLD |
|
|
180 kw Cummins (Enclosed, 6 Cyl. Cummins, 894 Hours, Mfg. 2000) Natural Gas/LP Genset
180 KW CUMMINS NATURAL GAS OR PROPANE GENERATOR
-Mfg. 2000 -Newage Stamford Generator End -Continuous Rated at 180 kw / 225 kva -Currently Setup 277/480 Volt, 3 Phase -12 Lead Reconnectable -60 Hertz, 1800 RPM -24 Battery Volts -Powered by an Inline 6 Cylinder Turbocharged Cummins Natural Gas / Propane Engine -Model Number: GTA12 -Engine Number: 25247619 -Rated 280 HP @ 1800 RPM -Compression Ratio: 8.5:1 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -PowerCommand 3100 Digital Control Panel -240/600 Amp 3 Pole Adjustable Merlin Gerin Mainline Circuit Breaker (Set at 502 Amps) -Jacket Water Heater -Alternator -Electronic Governor -Altronic Ignition System -Muffler (Mounted Outside Enclosure) -894 Total Hours Since New -Video Available -Dimensions: 144"L x 62"W x 115"H -LOAD BANK TESTED -- SOLD |
|
|
200 kw Cummins (Enclosed, 6 Cyl. Cummins, 625 Hours, Mfg. 1994) Natural Gas/LP Genset
200 KW CUMMINS NATURAL GAS / PROPANE GENERATOR
-Mfg. 1994 -Newage Stamford Generator End -Type: UCI274H13 -AVR: MX341 -Serial Number: H940551479 -Standby Rated at 200 kw / 250 kva -Currently Setup 277/480 Volt, 3 Phase (301 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -24 Battery Volts -Powered by an Inline 6 Cylinder Turbocharged Cummins Natural Gas / Propane Engine -Model Number: GTA855B -Serial Number: 55100209 -Rated 354 HP @ 1800 RPM -Compression Ratio: 8.5:1 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -Detector Analog Control Panel -400 Amp 3 Pole GE Mainline Circuit Breaker -Jacket Water Heater -Alternator -Battery Charger -Barber Colman Electronic Governor -Altronic Ignition System -Muffler (Mounted Outside Enclosure) -CSA Approved -625 Total Hours Since New -Video Available -Dimensions: 145"L x 62"W x 114"H -- SOLD |
|
|
250 kw Lynx / Doosan (Enclosed, V8 Engine, 488 Hours, Mfg. 2005) Natural Gas/LP Genset
250 KW LYNX / DOOSAN NATURAL GAS GENERATOR
-Mfg. 2005 -Model Number: 250SG -Serial Number: H02SG1570 -Standby Rated -Currently Setup 120/208 Volt, 3 Phase -12 Lead Reconnectable -60 Hertz, 1800 RPM -24 Battery Volts -Powered by a V8 Twin Turbocharged Doosan Natural Gas Engine -Model Number: GV158T1C -Serial Number: 601218 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -GM 250 Control Panel -Jacket Water Heater -Alternator -Battery Charger -Woodward Electronic Governor -Altronic Ignition System -Muffler (Mounted Outside Enclosure) -Dry Weight (Approx.): 8,360 lbs. -488 Total Hours Since New -Video Available -Dimensions: 147"L x 71"W x 95"H -- SOLD |
|
|
270 kw Caterpillar (Open Skid, Model 3408, 259 Hours, Mfg. 1993) Natural Gas/LP Genset
270 KW CATERPILLAR NATURAL GAS GENERATOR
-Mfg. 1993 -Generator End Model Number: SR-4 -Generator End Serial Number: 6CA00935 -Prime Rated at 270 kw / 338 kva -Currently Setup 277/480 Volt, 3 Phase (406 Amps) -10 Lead Reconnectable (277/480 Volt or 120/208 Volt, 3 Phase Only) -60 Hertz, 1800 RPM -24 Battery Volts -Powered by an 18.0L Caterpillar V8 Turbocharged Natural Gas Engine -Engine Model Number: 3408 -Engine Serial Number: 6NB01028 -Compression Ratio: 9.7:1 -Skid-Mounted -Radiator Cooled -Open Frame -Analog Control Panel -600 Amp 3 Pole GE Mainline Circuit Breaker -Jacket Water Heater -Alternator -Woodward Mechanical Governor (w/ Electric Speed Adjust) -259 Total Hours Since New -Video Available -Dimensions: 130"L x 59"W x 78"H -- SOLD |
|
|
300 kw Elliott / Cummins (Enclosed, 19.0L 6 Cyl. Cummins, 404 Hours, Mfg. 2000) Natural Gas/LP Genset
300 KW ELLIOTT / CUMMINS NATURAL GAS GENERATOR
-Mfg. 2000 -Model Number: 300 RN -Serial Number: BW01J626 -Standby Rated at 300 kw, 3 Phase or 235 kw, Single Phase -Currently Setup 277/480 Volt, 3 Phase (451 Amps) -12 Lead Reconnectable -60 Hertz, 1800 RPM -24 Battery Volts -Powered by a 19.0L Inline 6 Cylinder Turbocharged Cummins Natural Gas Engine -Model Number: GTA19G1 -Engine Number: 25266165 -Rated 495 HP @ 1800 RPM -Compression Ratio: 10:1 -Skid-Mounted -Radiator Cooled -Weatherproof Enclosure -DynaGen TG410 Digital Control Panel -500 Amp 3 Pole ABB Mainline Circuit Breaker -Jacket Water Heater -Alternator -Battery Charger -Woodward Electronic Governor -Altronic Ignition System -Muffler (Mounted Outside Enclosure) -404 Total Hours Since New -Video Available -Dry Weight (Approx.): 9,955 lbs. -Dimensions: 148"L x 64"W x 112"H -- SOLD |